Revision information – Yokogawa EJA530E User Manual

Page 51

Advertising
background image

i

IM 01C25F01-01E

Revision Information

Title

: Absolute Pressure and Gauge Pressure Transmitters

EJ510, EJ530, EJX610A and EJX630A

Manual No. : IM 01C25F01-01E

Edition

Date

Page

Revised Item

1st

Aug. 2004

New publication.

2nd

Feb. 2005

Re-number figure and table title.

2.

Revise words and phrases.

2-3

2.9.1

• Add 'a. FM Intrinsically safe Approval.'

2-5

• Add 'c. FM Intrinsically safe/FM Explosionproof Type.'

2-5

2.9.2

• Add subsection '2.9.2 CSA Certification.'

2-7

2.9.3(1)

• Add 'a. CENELEC ATEX (KEMA) Intrinsically safe Type.'

2-8

• Correct number in Note 4. 10 MINUTES → 5 MINUTES
• Add 'c. CENELEC ATEX (KEMA) Intrinsically safe Type/

CENELEC ATEX(KEMA) Flameproof Type/CENELEC ATEX

Type n.'

3-1

3.

• Add descriptions in Note 2.

4-2

4.4

• Add subsection 4.4.

7-1

7.1

• Delete unnecessary description.

8-4

8.4.2

• Correct calbe color in 1). black → white

8-5

8.4.3

• Add description about stopper in 1).

9-1 to 9-5

9.

• Add notes for FOUNDATION fieldbus communication type.

9-1

9.1

• Correct Span & Range Limits.
• Correct Burst Pressure Limits.

9-5

9.3

• Add codes for CSA approval and note *3.

3rd

July 2006

2-3 to 2-10

• Add/change applicable standards.

2-6

2.9.2

• Add descriptions for Note 2.

2-11

2.10

• Change reference number for Australian standard.

2-11

2.11

• Add descriptions for European Pressure Equipment Directive.

2-12

• Add "2.12 Low Voltage Directive."

9-3

9.1

• Add descriptions for stainless steel housing.

9-4

9.2

• Add amplifier housing code 2.

9-5

9.3

• Add code of /SU2.

9-6

9.3

• Add code of /PE3.

4th

Feb. 2008

Change of the style code.

General

• Change the figure of amplifier housing.

1-1

1

• Add style code table.

2-1

2.1

• Update the Figure 2.2.

2-5

2.9.1

• Add code /V1U.

2-6

2.9.2

• Revise information for CSA Explosionproof type.

2-7

2.9.2

• Add code /V1U.

2-7 to 2-8

2.9.3

• Revise information for KEMA flameproof type. Add code /V1U.

2-9

2.9.3

• Revise Figure in (2) Electrical connection and (6) Nameplate.

2-10

2.9.4

• Revise information for IECEx flameproof type.

9-3

9.1

• Revise weight information.

9-4

9.2

• Add new suffix codes for 316 SST blind plugs and brackets.

9-5

9.3

• Remove /KF2 and /KU2. Add /KF21, /KU21, /SF2 and /V1U.

9-6

• Add /HC.

9-7

9.4

• Revise external dimensions.

5th

Aug. 2009

2.1

2.1

• Replace a name plate.

2-6

2.9.2

• Correct certificate No. for CSA explosionproof type.

2-10

2.10

• Revise standards.

2-11 to 2-12

2.11

• Revise information of PED.

9-5

9.3

• Add process sealing statement for CSA approval.

9-6

9.3

• Add /A1, and /DG6.

Advertising
This manual is related to the following products: