OPTION SPECIFICATIONS

Limit switch (option /GM1 to /GM5):

( for P- tubes with PVDF- or SS- float with magnet only)

Type

: reed contact with bistable switching

Max. switching voltage : 230 V

Max. switching current : 2 A

Max. switching capacity : 40 W/VA

Temperature range : -10°C to +70°C

Protection

: IP65

Internal capacity

: 0 nF

Internal inductivity : 0 mH

Electrical connection : LIYY 2 x 0.34 mm²; length 1 m

Housing

: Polystyrene

Weight

: 35 g

Explosion proof

:

Intrinsic safe acc. EN 60079-11 chapter 5.7,

IEC 60079-11 chapter 5.7 and ANSI/ISA 60079-11

chapter 5.7 as "Simple Apparatus".

Group

: IIC

Category

: 2G

Temperature class : T6

Entity parameter : Ui = 15 V ; Ii = 50 mA ; Pi = 187 mW

Li ≈ 0 mH ; Ci ≈ 0 nF

Limit switch (option /GR2 to /GR8):

(for L- tubes with PVDF float only)

Type

: Bistable inductive ring sensor

Power supply

: 4.5 V to 15 V DC

Consumption

: acc. DIN EN 60947-5-6 (NAMUR)

Float below ring sensor : < 1 mA

Float above ring sensor : > 2.2 mA

Temperature range : -25°C to +65°C non-Ex- type

Protection

: IP 67

Electrical connection : 2 x 0.14 mm² , with shield 0.4 mm²,

2 m long

Explosion proof type (option /KS1):

Temperature range : -25°C to +60°C

Marking acc. guideline 94/9/EG :

Manufacturer : Rota Yokogawa, Rheinstr.8,

D-79664 Wehr

Type

: RI20-10K/G or RI20-17K/G

Year of production : in serial number

Protection

: Ex ia

Group

:

IIC

Category

: 2G

Temperature class : T6

Certificate No. : PTB 03ATEX 2111

Safety relevant data (see also certificate for data):

Ui = 12 V, Ii = 22 mA , Pi = 66 mW,

Li = 20 mH, Ci = 200 nF

CE-marking

:

II 2 G

Power supply for limit switch (option /W__):
Type : acc. DIN EN 60947-5-6 (NAMUR)

- KFA5-SR2-Ex*-W (115 V AC), * = 1 or 2

- KFA6-SR2-Ex*-W (230 V AC), * = 1 or 2

- KFD2-SR2-Ex*-W (24 V DC), * = 1 or 2

- KHA6-SH-Ex1 (115/230 V AC), Fail Safe, 1 channel

- KFD2-SH-Ex1 (24 V DC), Fail Safe, 1 channel

Power supply :

- 230 V AC ± 10%, 45-65Hz

- 115 V AC ± 10%, 45-65Hz

- 24 V DC ± 25%

Relay output :

1 or 2 potential-free changeover contact(s)

Switching capacity :

max. 250 V AC, max. 2 A

STANDARD SPECIFICATIONS

Fluids to be measured : Liquids and gas

Measurable flow rates

:

- Water (20 °C)

: 0.002 l/h to 10 m3/h

- Air (20 °C; 1 bar abs.) : 0.1 l/h to 160 m3/h

Turndown

:

- P metering tube

: 10:1

- L metering tube

: 20:1

Metering tubes

: L6; L7; P0; P1; P2; P4 (length 300 mm)

Process temperature

: -25°C to +100°C

Process pressure

:

Metering tube

L6;L7

P0;P1

P2

P4

Pmax (bar)

16

10

8

6

Installation length

:

Process connection

Thread

Clamp

Flange

Length [mm]

375

375

425

Weight

: Depending on design (see page 7)

Accuracy

:

Tube

Measuring accuracy acc.

Directive VDI/VDE 3513 sheet 2 (q

G

= 50%)

L613 - L623

2.5%

L624 - L747

1.6%

P051 - P471

1.6%

Materials

:

Threads G, NPT

: AISI 316L (1.4404)

Flange EN / ASME

: AISI 316L (1.4404)

Clamp ISO 2852

: AISI 316L (1.4404)

Housing

: AISI 304 (1.4301)

Nut

: AISI 316 (1.4401) (or galvanized steel)

Stoppers (L6, L7 tube) : PFA

Stoppers (P0 - P4 tube) : PVDF, AISI 316L (1.4404)

Measuring cone

: Borosilicate glass

Float (L6, L7 tube )

: Titanium, PVDF

Float (P0 - P4 tube)

: PTFE, PVDF (FDA conform),

AISI 316Ti (1.4571)

Gaskets

: NBR, FKM,EPDM (FDA conform)

Pressure Equipment Directive (PED) Directive 97/23/EG:

Models

: RAGN04, RAGN05, RAGN06

Tubes :

- Modul

: A

- Fluid Group

: 1 (liquid, gases)

- Produced acc. to category

: I

FDA-Conformity:

RAGN with P- tube, PVDF- or SS- float and EPDM- gaskets

(option /ME).

Stoppers and floats made of PVDF:

21 CFR § 177 2510(a)

O-rings made of EPDM:

21 CFR § 177 2600-21

Compliance with safety application acc. IEC 61508: 2010

and ISO 13849:

Please refer to the FMEDA report and instruction manual.