Options – Yokogawa RAGN User Manual

Page 37

Advertising
background image

<8. TECHNICAL DATA>

8-5

IM 01R01B10-00E-E 2nd edition: November 01, 2011-00

All Rights Reserved. Copyright © 2011, Rota Yokogawa

OPTIONS

Options

Option
Code

Description

Restriction

Marking

/B1
/B4
/BG
/B10
/BD

Tag plate (SS)
Neutral version
Customer specific notes on name plate
Percentage scale
Dual scale

Plate 12 x 40 mm; max. 45 digits
Not with /KS1
Max. 45 digits

Only for tube P

Limit switches

/GM1

/GM2

/GM3

/GM4

/GM5

/GR2
/GR3
/GR4
/GR6
/GR7
/GR8
/GD1
/GD2

Magnetic MIN-contact

Magnetic MAX-contact

Magnetic MIN-MAX-contact

Magnetic MIN-MIN-contact

Magnetic MAX-MAX-contact

Bistable inductive ring sensor
Bistable inductive ring sensor
Bistable inductive ring sensor
2 bistable inductive ring sensors
2 bistable inductive ring sensors
2 bistable inductive ring sensors
Connection box for 1 limit switch
Connection box for 2 limit switches

Only for tube P0 to P4 and float
insertion code M (with magnet)
Only for tube P0 to P4 and float
insertion code M (with magnet)
Only for tube P0 to P4 and float
insertion code M (with magnet)
Only for tube P0 to P4 and float
insertion code M (with magnet)
Only for tube P0 to P4 and float
insertion code M (with magnet)
Only for tube L6 with float code PDB
Only for tube L7 with float code PDC
Only for tube L7 with float code PDD
Only for tube L6 with float code PDB
Only for tube L7 with float code PDC
Only for tube L7 with float code PDD
Only with /GM1 to 2, /GR2 to 4
Only with /GM3 to 5, /GR6 to 8

Ex-proof type

/KS1

ATEX intrinsically safe „ia“

Only for /GR2 to /GR8

Installation lengths
(s. also table on page 8-6)

/L12
/L13
/L14
/L15
/L16

Installation length 500 mm
Installation length 356 mm
Installation length 368 mm
Installation length 386 mm
Installation length 394 mm

Only for D4, A1
Only for size 01 and G0, T0
Only for size 01, 23, 02 and G0, T0
Only for size 02, 04 and G0, T0
Only for size 05, 06 and G0, T0

Valves
(inner thread,
double fitting is attached,
not for FDA)

/V1
/V2
/V3
/V4
/V5
/V6

Valve made of 1.4571 G ½´´ (parts attached)
Valve made of 1.4571 G 1´´ (parts attached)
Valve made of 1.4571 G 1½´´ (parts attached)
Valve made of brass G ½´´ (parts attached)
Valve made of brass G 1´´ (parts attached)
Valve made of brass G 1½´´ (parts attached)

Only for G0 and tube L6, L7, P0
Only for G0 and tube P1
Only for G0 and tube P2
Only for G0 and tube L6, L7, P0
Only for G0 and tube P1
Only for G0 and tube P2

Test and certificates

/H1
/P2
/P3
/P6

/PP
/PT
/PM2

/PM4

Oil + fat free for wetted surfaces acc. Yokogawa specification
Certificate of Compliance with the order acc. EN 10204: 2004- 2.1
As /P2 +Test report acc. to EN 10204: 2004- 2.2
Material certificate for Insertion parts or flange connections
acc. EN 10204: 2004- 3.1
Pressure test report for metering system
With flow table for recalculation + mm- scale
PAMI test (2 test points)

PAMI test (4 test points)

Only for insertion and flange
connections
Not with /V1 to /V6

Only for connections G0, T0, S4
except RAGN04-G0SS-P2 and
RAGN04-T0SS-P2
Only for connections A1, D4 and
RAGN04-G0SS-P2 and
RAGN04-T0SS-P2

Delivery to Korea

/KC

With KC-mark in Korea

Accessories for metering
tube

/MV
/ME
/MN

Gasket FKM (Viton)
Gasket EPDM (conform to FDA, -30°C to +100°C)
Nut galvanized steel

conform with FDA -30°C to +100°C
not for S4 and RAGN04 with P2

Power supply for limit
switches (transmitter
relay)

/W1A
/W1B
/W2A
/W2B
/W2E
/W2F
/W4A
/W4B
/W4E
/W4F

KFA5-SR2-Ex1.W / 115 V AC, 1 channel
KFA5-SR2-Ex2.W / 115 V AC, 2 channel
KFA6-SR2-Ex1.W / 230 V AC, 1 channel
KFA6-SR2-Ex2.W / 230 V AC, 2 channel
KHA6-SH-Ex1 / 115/230 V AC, 1 channel, Fail Safe
2x KHA6-SH-Ex1 / 115/230 V AC, 1 channel, Fail Safe
KFD2-SR2-Ex1.W / 24 V DC, 1 channel
KFD2-SR2-Ex2.W / 24 V DC, 2 channel
KFD2-SH-Ex1 / 24 V DC, 1 channel, Fail Safe
2x KFD2-SH-Ex1 / 24 V DC, 1 channel, Fail Safe

Instruction manuals

/IEn
/IDn

Quantity of instruction manuals in English
Quantity of instruction manuals in German

n = 1 to 9 selectable *)
n = 1 to 9 selectable *)

Special order

/Z

Special design must be specified in an extra text.

*) If no instruction manual is selected, only a Short IM and in case of limit switches a CD with instruction manuals is shipped with the flowmeter.

Advertising