DAQSTANDARD for DXAdvanced

The functions below have been added or changed since DAQSTANDARD revision 7.21.

Hardware Configurator

Setup Menu Corresponding to the DX Functions of Firmware Version 2.0x
• Specifying the Base Position of the Bar Graph

Applies to the operations on the [Measure channel], [Math channel], or [Ext channel]

tab screen.

Bar Display Position

Set the base position of the bar graphs to [Normal], [Center], [Lower], or [Upper].

Operations on the DX1000/DX1000N/DX2000: Page 6

• Alarm Output Relay Action When the Alarm ACK Operation Is Executed

Select [Alarm] on the [Basic Setting] tab screen.

Relay Action on ACK

Normal The relay output is deactivated when the alarm ACK operation is executed.

If the condition for activating the alarm output relay is met in the next scan
interval, the relay output is activated.

This operation is valid only when the alarm output relay is set to [Hold].
Reset The relay output is deactivated when the alarm ACK operation is executed. If

a new condition for activating the alarm output relay, the relay is activated.

Operations on the DX1000/DX1000N/DX2000: Page 9

• Storage Method for Constantly Retaining the Most Recent Data Files in

the CF Card (Media FIFO)

Select [Environment] > [Detail Setting] on the [Basic Setting] tab screen.

Media FIFO

This is valid only when [Auto Save] is [ON].

ON If there is no more free space on the CF card, the oldest file is deleted, and the

newest file is saved.

OFF If there is no more free space on the CF card, the measured data is not saved to

the CF card.

Operations on the DX1000/DX1000N/DX2000: Page 12

Advertising