89

Installation and W

iring

Recommended Replacement

Periods for W

orn Parts

Setup Items and

Default V

alues

IM 04L42B01-02E

Setup Items and Default Values

Communication (Ethernet) > IP-address, Host settings

Setup Item

Selectable Range or Selections

Default Value

Setting

DHCP

Use/Not

Not

DNS accession

Use/Not

Use

Host-name register

Use/Not

Use

Fixed IP-address > IP-address
Fixed IP-address > Subnet mask
Fixed IP-address > Default gateway

0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255

0.0.0.0
0.0.0.0
0.0.0.0

Host settings > Host name

64 characters or less

Host settings > Domain name

64 characters or less

Communication (Ethernet) > DNS settings

Setup Item

Selectable Range or Selections

Default Value

Setting

Server search order > Primary
Server search order > Secondary

0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255

0.0.0.0
0.0.0.0

Domain suffix search order > Primary
Domain suffix search order > Secondary

64 characters or less
64 characters or less


Communication (Ethernet) > Keep alive, Application time out

Setup Item

Selectable Range or Selections

Default Value

Setting

Keep alive

On/Off

On

Application time out > On/Off
Application time out > Time

On/Off
1 to 120 (min)

Off
1

Communication(Ethernet) > Server > Server modes

Setup Item

Selectable Range or Selections

Default Value

Setting

FTP

Use/Not

Use

*2

Web

Use/Not

Use

*1

SNTP

Use/Not

Not

Modbus

Use/Not

Not

EtherNet/IP

*2

Use/Not

Not

Communication(Ethernet) > Server > Allowed Modbus clients

*2

Setup Item

Selectable Range or Selections

Default Value

Setting

Use/Not

Use/Not

Not

Client number

1/2/3/4/5/6/7/8/9/10

1

On/Off

On/Off

Off

Communication (Ethernet) > Web page

Setup Item

Selectable Range or Selections

Default Value

Setting

Without /AS1

Page type

Operator/Monitor

Operator

Page type=Operator

Web page > On/Off
Web page > Access control
Web page > Command

On/Off
Off/Admin
Use/Not

Off
Off
Not

Page type=Monitor

Web page > On/Off
Web page > Access control

On/Off
Off/Admin/User

Off
Off

With /AS1

*3

Page type

Operator/Monitor

Operator

Page type=Operator

Web page > On/Off

On/Off

Off

Web page > Access control

Off/Admin

Off

The items when Page type is set to Monitor are the same as on a DX without the /AS1 option.