2 text data output format, 2 text data output format -6, Setting data/basic setting data – Yokogawa Button Operated MV2000 User Manual

Page 125

Advertising
background image

5-6

IM MV1000-17E

5.2 Text Data Output Format

The table below lists the available text data types. This section will explain each format.
The table below indicates the data types and the corresponding output commands.

Data Type

Corresponding Output Command

Setting data/basic setting data

FE0,FE2

Decimal place and unit information

FE1

Measured, computed, and external input data

FD0

Relay and internal switch status

FD6

Communication log

FLCOM

FTP client log

FLFTPC

Operation error log

FLERR

Login log

FLLOGIN

Web operation log

FLWEB

E-mail log

FLEMAIL

SNTP access log

FLSNTP

DHCP access log

FLDHCP

Modbus communication log

FLMODBUS

Alarm summary

FLALARM

Message summary

FLMSG

Status information

IS0,IS1

Ethernet information

FAIP

File list

MEDIR

Check disk result

MECHKDSK

Manually sampled data and report data information

MODIR

User information

FU0,FU1

Note

CRLF” used in this section denotes carriage return line feed.

Setting Data/Basic Setting Data

• The MV returns the setting/basic setting data in response to an FE command.
• The MV returns the data in order as listed in the table in section 4.2, “A List of

Commands.” However, the MV does not return the setting data for the following
commands.

• Setting commands (setting)

SD and FR commands

• Setting commands (control)

All commands from BT to IR

• Basic setting commands

XE, YO, YE, and YC commands

• The output format of the setting/basic setting data conforms to the syntax of each

command.

• The MV returns multiple lines for some commands (for example, commands that are

specified for each channel).

• Syntax

The MV returns the two-character command name and subsequent parameters in the

following syntax.
EACRLF
ttsss···sCRLF
··············
ENCRLF

Advertising
This manual is related to the following products: