Yokogawa Standalone MW100 User Manual

Page 10

Advertising
background image

10/17

4. Communication Commands

4.1.Setting the Input Range

When setting p2=SKIP
SR p1,p2<terminator>

When p2=COM
When p6=OFF
SR p1,p2,p3,p4,p5,p6<terminator>
When p6=DELTA
SR p1,p2,p3,p4,p5,p6,p7<terminator>
When p6=SCALE
SR p1,p2,p3,p4,p5,p6,p7,p8,p9,p10<terminator>

When Setting Channels to SKIP

Syntax SR

p1,p2<terminator>

p1

Channel range (001–060)

p2

Input mode (SKIP)

Query SR[p1]?

Example)

Set channel 1 to SKIP.

SR 001,SKIP
Explanation)

Channels set to SKIP are not measured.

Specify measurement channels on p1.

When Setting Channels to COM

When no computation performed

Syntax SR

p1,p2,p3,p4,p5,p6<terminator>

p1

Channel range (001–060)

p2

Input mode (COM)

p3

Measurement range (CAN)

p4

Lower limit of span (-30000–30000)

p5

Upper limit of span (-30000–30000)

p6

Computation mode (OFF)

Query SR[

p1]?

Example)

Set the input type for channels 1–10 to COM(CAN), the lower limit

span to 0, and the upper limit of span to 10000.

SR 01-10,COM,CAN,0,10000,OFF
Explanation)

Specify

measurement channels on p1.

Advertising