4-7

Using CopyT

ool

1

2

3

4

Index

IM 04P01B01-61E

3.

Specify a settings file to send.

The extension for settings files is .pul.

Enter a path to the settings file using up to 256 alphanumeric characters.

Click to display a file selection

dialog box.

4.

Specify whether to send communication settings.

If you select the

Send communication command check box (turns blue), the

settings below are also sent.

• Host and domain name settings
• IP address setting
• DNS setting
• Use/do not use Login function
• User-specific settings for Login function
• Communication timeout setting
• Keep alive setting
• Serial interface settings

To enable the communication parameters in the settings file that was sent (for

example, the baud rate), after sending is complete, turn the power to the recorder
OFF, then ON again.

Note that if the communication mode in the sent settings file does not match that of

the recorder (for example, if the communication mode in the file is Ethernet but that of
the recorder is RS422), the send fails.

4.3 Copying Recorder Settings