List of parameters – Yokogawa JUXTA VJU7 User Manual

Page 7

Advertising
background image

7

IM 77J01U07-01E

4th Edition Feb. 09, 2007-00

11. LIST OF PARAMETERS

No. Item

Display

01

Model

MODEL

02

Tag No.

TAG NO

03

Self-check result

SELF CHK

Display

items

A Display

1

DISPLAY1

A01

Input

value

INPUT1

A05

Output value 1

OUTPUT1

A06

Output value 2

OUTPUT2

A07

Alarm-1 status

ALM1 STATUS

A08

Alarm-2 status

ALM2 STATUS

A54

Status

STATUS

(*1)

A56

Rev No.

REV NO

A58

Menu Rev

MENU REV

A60

Self-check result

SELF CHK

Setting items

(*2) (*3)

D Setting

(I/O)

SET(I/O)

D01

Tag no.1

TAG NO.1

D02

Tag no.2

TAG NO.2

D03

Comment

1

COMMENT1

D04

Comment

2

COMMENT2

D07

Input sensor type

SENSOR TYPE

D08

Thermocouple

type

TC

TYPE

D09

RTD

type

RTD

TYPE

D15

Unit

UNIT

D17

Input hard range selection

SELECT RANGE

D22

Input low range

INPUT1 L_RNG

D23

Input high range

INPUT1 H_RNG

D30

Burnout

BURN

OUT

D38

Direction of output-1 action

OUT1 DR

D39

Direction of output-2 action

OUT2 DR

D60

Self-check result

SELF CHK

Adjusting

items

(*3)

P Adjustment

ADJUST1

P01

Wiring resistance correction

WIRING R

P02

Zero adjustment of input 1

ZERO ADJ1

P03

Span adjustment of input 1

SPAN ADJ1

P12

0% adjustment of output 1

OUT1 0%

P13

100% adjustment of output 1

OUT1 100%

P14

0% adjustment of output 2

OUT2 0%

P15

100% adjustment of output 2

OUT2 100%

P60

Self-check result

SELF CHK

No. Item

Display





B Display

2

DISPLAY2

B01

Input

value

INPUT1

B05

Output value 1

OUTPUT1

B06

Output value 2

OUTPUT2

B07

Alarm-1 status

ALM1 STATUS

B08

Alarm-2 status

ALM2 STATUS

B60

Self-check result

SELF CHK





E

Setting (alarm output)

SET(ALM)

E01

Alarm-1 setting

SET POINT1

E02

Alarm-2 setting

SET POINT2

E03

Alarm-1 setting

SET POINT1

E04

Alarm-2 setting

SET POINT2

E05

Direction of alarm-1 action

ALM1 ACTION

E06

Direction of alarm-2 action

ALM2 ACTION

E07

Alarm-1

hysteresis

HYSTERESIS1

E08

Alarm-2

hysteresis

HYSTERESIS2

E09

Alarm-1

hysteresis

HYSTERESIS1

E10

Alarm-2

hysteresis

HYSTERESIS2

E11

Alarm-1 ON delay setting

ON DELAY1

E12

Alarm-2 ON delay setting

ON DELAY2

E13

Alarm-1 OFF delay setting

OFF DELAY1

E14

Alarm-2 OFF delay setting

OFF DELAY2

E15

Direction of alarm-1 relay action

RL1 ACTION

E16

Direction of alarm-2 relay action

RL2 ACTION

E60

Self-check result

SELF CHK

F

Setting

(communication)

SET(COM)

F01

Communication

protocol

PROTOCOL

F02

Address

ADDRESS

F03

Baud rate

BAUD RATE

F04

Parity

PARITY

F05

Data length

DATA LEN

F06

Stop bit

STOP BIT

F07

Decimal point position

INPUT DEC PT

F60

Self-check result

SELF CHK

Test items

(*3)

Q Test

TEST

Q01

ON/OFF of RJC

RJC

Q02

Forced output 1

OUT1 TEST

Q03

Forced output 2

OUT2 TEST

Q04

Forced output (alarm 1)

ALM1 TEST

Q05

Forced output (alarm 2)

ALM2 TEST

Q60

Self-check result

SELF CHK

*1 : The status is displayed for service personnel to see history records.
*2 : Some items are not displayed depending on the selected input sensor type or output-2 specification.
*3 : To call the parameter setting items D, E, F, P and Q using the JHT200 Handy Terminal, execute the following operation:

Press F1 ENTER keys.

D, E, F, P or Q key enters above.