Appendixes – MAHLE RTI RHS900 User Manual

Page 45

Advertising
background image

- 13.1 -


Appendixes



C:\RHS Computer Files\Instructions\RHS\GB\642-40\0012B-01.doc 1997.09.11
RHS 900

Example of trouble shooting in an A/C unit:


Conditions:

1.

Ambient temperature

30-35°C (86-95°F)


2.

Motor speed

2000 rpm


3.

A/C unit temperature setting

Maximum




Under the above conditions the pressure values for an intact A/C unit will be
as follows during the TEST process:

High pressure

15 bar


Low pressure

2 bar



Follow the TEST process as in Section 5:

-

Connect service couplings to A/C unit.


-

Close high and low-pressure valves on RHS 500.


-

Open service coupling valves.


-

Start in A/C unit.


-

Now the station will perform a test function.

Perform a condition diagnosis for the A/C unit in accordance with supplier
instructions.


-

Stop A/C unit after the test process has been completed.