- 13.4 -


Appendixes



C:\RHS Computer Files\Instructions\RHS\GB\642-40\0012B-01.doc 1997.09.11
RHS 900

Test - 5:

High pressure

Approx.
19 - 20 bar

Low pressure

Approx.
2.5 bar


Fault/Problem Symptom

Possible

cause

Remedy

Unacceptable
refrigeration

Ice or moisture on
hoses on low
pressure/suction side
of A/C unit

Expansion valve
defective or sensor
placed incorrectly.
Expansion valve opens
too much.

Check expansion
valve sensor
placing.
Replace expansion
valve.




Test - 6:

High pressure

Approx.
7 - 10 bar

Low pressure

Approx.
4 - 6 bar


Fault/Problem Symptom

Possible

cause

Remedy

A/C unit does not
refrigerate

Pressure on low-
pressure side too
high or pressure on
high-pressure side
too low

Internal compressor
leakage

Repair or replace
compressor