Nexo RS User Manual

Page 20

Advertising
background image

Page 20/54

A

MPLIFIER SELECTION FOR USE WITH

RS18

2) With a signal generator, feed a sine wave at 1000Hz at a known voltage (say 0.5V) to

the input of the amplifier under test

3) Measure the voltage at the output of the amplifier

4) Calculate the gain using the formula Gain = 20 * LOG

10

(Vout/Vin).

Some examples:

Vin / Gain

20dB

26dB

32dB

37dB (1.4V sensitivity / 1350Wrms)

0.1 V

1 V

2 V

4 V

7.1 V

0.5 V

5 V

10 V

20 V

35.4 V

1 V

10 V

20 V

40 V

70.8 V

Remember that constant sensitivity settings will give a different gain value when the amplifier power is
different.

NEXO recommends low gain amplifiers: +26dB is recommended, as it is at the same time adequately
low and quite common amongst amplifier manufacturers. This gain setting improves signal to noise ratio
and allows all preceding electronic equipment, including the NX242-ES4 TDcontroller, to operate at
optimum level. Remember that using a high gain amplifier will raise the noise floor proportionally.

Operating Mode

Most two channel amplifiers available on the pro-audio market have the following operating modes:

• Stereo: two fully independent channels deliver identical power into identical loads
• Bridge-Mono: the second signal channel processes the same input as the first channel, but with

reversed phase. The (single) load is connected between the two positive channel outputs using a
suitable connection. While the total output of the amplifier remains the same, the available output
voltage, the minimum impedance that can be connected and the voltage gain are doubled as
compared with stereo operation. Typically, only channel 1 input is active. Positive and negative output
connections vary depending on amplifier manufacturers.

• NEXO does not recommend Bridge Mono Mode unless amplifier power is clearly not sufficient.

IMPORTANT

When in Bridge-Mono mode, check your amplifier user manual for proper connection of
outputs 1(+) and (2+) in relation to input phase.

• Parallel-mono: the output terminals of the two channels are configured in parallel using an internal

relay. The (single) load is connected either to the output of channel 1 or to that of channel 2 (as if in
stereo). While the total output of the amplifier remains the same the output voltage level is also the
same as in stereo mode. The minimum impedance that can be connected is reduced by half due to
the fact that current capability is doubled. Typically, only channel 1 input is active.

• NEXO does not recommend Parallel-Mono Mode for RS18 amplification.

Warning on amplifiers signal processing features

Some high-end amplifiers may include signal processing functions similar to those found in the NX242-
ES4 TDcontroller ("loudspeaker offset integration", "limiter", "compressor," etc.). Moreover, when this
processing is digital, computation latency time can introduce a few milliseconds delay from input to
output. These functions are not adapted to specific system requirements and may interfere with the
complex protection algorithms used in the NX242-ES4.

NEXO do not advise using other protection systems in conjunction with the NX242-ES4 and they should
be disabled.

IMPORTANT

For proper system protection, no latency time or non-linear devices should be inserted
between the output of NX242-ES4 TDController and the input of loudspeakers through
use of DSP modules such as internal amplifier signal processing.

Advertising
This manual is related to the following products: