“FACE TO FACE“ CONFIGURATION

7.2.3 RS18s

arrays

IMPORTANT

RS18s arrays must be installed with bumper set horizontally and all cabinets at 0°.

Flying RS18s columns can significantly improve low frequency coverage in the vertical plane, and
therefore over audience depth provided height is sufficient.

A 10 RS18 cluster flown at 10m/30ft will provide a +/- 3dB pressure level deviation at 100Hz over an
audience area 75m/200ft deep while maintaining 15 to 20dB attenuation on stage (see figure below).

10 RS18 CLUSTER OVER 75M/200FT