Heater Problems
Symptom

Solution

No heat

1.

This may be caused by a dirty filter: Clean

the filter per the instructions provided in the

Maintenance section of this manual. If the filter

is more than two months old, replace it. After

cleaning or replacing the filter, cover the spa, turn

the temperature set point all the way up, and leave

the spa for 24 hours. If the spa still will not heat,

contact the manufacturer for instructions.

No heat and no

circulation

1.

The water pump may be air bound: Unplug the

power pack from the electrical outlet. Bleed air

from the filter tank by turning the bleed fitting

on the top of the filter tank counter-clockwise.

After one minute, or when water drips from the

fitting, close the bleed fitting and plug in. If the

water pump still does not pump water, contact

the manufacturer for instructions.

If the water pump becomes air bound again,

check the o-ring on the top of the filter tank.

Refer to the filter changing instructions in the

Maintenance section of this manual. Replace the

o-ring if necessary.

No heat and

no temperature

display

1.

Bad power pack: Ensure power is available to

the spa. Check the circuit breaker at the main

electrical panel. Connect another electrical

appliance to the plug used for the spa. If power

is available to the spa, test the GFCI using the

instructions supplied in the Maintenance section.

If the GFCI is working properly and the power

pack does not function, then the power pack

may have an internal component problem. If the

GFCI is not working properly, do not use the

spa. Immediately contact the manufacturer for

instructions.

Advertising