Step 1, Installation steps – Burcam 503721 CONVERTIBLE C.I. JET PUMP 3/4HP 115/230V User Manual

Page 3

Advertising
background image

3

APPLICATIONS

• This pump is designed for shallow well installation

for water level up to 25 feet, with injector screwed on

pump body; or for deep well installation for water level

up to 85 feet, with 2 pipes and injector down in

the well.
• CAPACITY AT 20 PSI

.

SHALLOW WELL

DEEP WELL

1/2 HP 3/4 HP

1/2 HP 3/4 HP

5’ 900

950

10’ 800

850

30’ 500

525

15’ 650

700

40’ 400

425

20’ 450

500

50’ 300

325

25’ 300

350

80’ 150

175

US GPH

US GPH

FEATURES

• High performance noryl impeller..

• Industrial motor totally enclosed, fan cooled.

• Full time connected run capacitor, to eliminate star-

ting wear vs regular motor.

• Thermal and overload protection.

• Built for a continuous use.

• 1/2 HP, 115/230 VCA, 60 Hz, 8.6 A/4.3 A

.

• 3/4 HP, 115/230 VCA, 60 Hz, 8.9 A/4.5 A

.

(at start : 15 A/7.5 A)

FRICTION LOSS IN PIPE

NOT INCLUDED.

FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029

INSTALLATION STEPS

We recommend that you install your pump in a clean and dry location where there is adequate room

for servicing at a later date. Protection from freezing temperatures and good ventilation should be

considered as well, to provide the pump an environment for long life. Locating the pump as close as

possible to the water source will reduce friction losses encountered in the suction pipe.
Friction losses in the suction pipe must be taken into consideration when the horizontal offset is greater

than 50 feet. The suction pipes should be increased from 1” to 1 1/4”. This will reduce friction losses and

allow the pump to give maximum performance.
A new well should be checked to determine that it is free from sand. Sand will damage the seal and the

impeller. Have your well driller clean the well before your installation.
Never run the pump dry. Damage to the seal may occur. Fill pump body and suction pipe with water

before turning on the power.
THE RUN OF HORIZONTAL PIPE FROM THE TOP OF YOUR WELL INTO THE HOUSE, WHERE

YOUR PUMP WILL BE LOCATED, MUST BE INSTALLED IN A TRENCH, BELOW THE FROST LEVEL

OF YOUR AREA.

STEP 1

Your ejector is factory pre-assembled with the venturi

510066.2, for an optimum performance when the

pumping level is between 25’ to 60’ (7.5 meters to 18

meters) depth, in reference to the pump position.

So, this is a deep well application mode. The ejector is

positioned into the well and is connected to the pump

using 2 pipes (see page 5).
If the pumping level is deeper than 60’ (18 meters)

in reference to the pump position, it is mandatory to

unscrew the pre-assembled venturi and to replace it

by the venturi 510066.3, also as a deep well mode

application with the ejector positioned into the well.
In the case of a pumping level lower than 25’ (7.5

meters), unscrew the pre-assembled venturi and replace

For deep well

application mode,

60’ and deeper.

For shallow

well application

mode.

Factory

pre-assembled, for

deep well application

mode, 25' à 60'.

510066.3

510066.2

510066.1

9/32"

21/64"

31/64"

7.1mm

8.3mm

12.2mm

it by the venturi 510066.1. Then screw the

ejector to the pump body. This becomes a shallow well mode application where only one pipe is required

to pump water (see page 4).