Booster pump application – Burcam 506532SS S.W. STAINLESS STEEL JET PUMP WITH FLUOMAC 3/4HP 115V User Manual
Page 7
![background image](/manuals/361739/7/background.png)
BOOSTER PUMP APPLICATION
2
3
1
2
3
1
OPEN
OPEN
OPEN
CLOSE
CLOSE
CLOSE
TO OPERATE
THE PUMP
TO SERVICE
THE PUMP
PRESSURE GAUGE
PRESSURE GAUGE
NEVER RUN THE PUMP DRY
To use this pump for pressure boosting, read carefully
the instructions for shallow well application, then
connect the pump to your water supply as per the
pictures on right.
Use appropriate union (not shown) to connect pipes for
an easy service at a later date .
If your incoming pressure is higher than 20 PSI, install a
pressure reducer (not shown) between the ball valve #1
and the pump, setted to 20 psi. This will prevent an
excess of pressure on the house distribution piping.
Install a pressure gauge as per the pictures on the right,
to monitor the pressure in piping.
Set the ball valves as per “to operate the pump” picture.
Open the nearest faucet and connect the pump to an
electrical outlet.
When all the air will be remove from the piping, close
the faucet. The pump will stop after 7 to 10 seconds.
Then, it will turn on when a faucet is open.
Flow
Flow
Flow
Flow
STEP 4
STEP 2
STEP 3
STEP 5
STEP 6
STEP 1
7
WARNING
In a booster pump application the
incoming pressure must never be
higher than 20 to 25PSI.
Minimum
pipe size 1’’
Minimum