PRIMING INSTRUCTIONS

STEP 8

STEP 9

STEP 10

STEP 12

STEP 11

Connect your discharge line, using a ball
valve, as illustrated. (photo 1)

Fill the suction line with water and connect it to
suction inlet (Photo 1).

Remove the plug of the priming pipe and fill
the pump body with water (Photo 1).

Screw the plug to the priming pipe using teflon
tape.(photo 2)

Connect the pump. The pump should
delivered water to the plumbing line within
30 seconds. If not, unplug the pump and
repeat from step 10. In accordance with
the lenght of your suction line, you may
have to repeat these steps a few times.

PHOTO 1

PHOTO 2

NOTE: After installation, if the pump is cycling “on-off” and/or comes on when you are not visibly using water,
the pump is not defective. It means you have a leak on the discharge side of the pump. The leak must be
localised and needs to be repaired. If you need assistance to determine same, please call 1-800.361.1820.
The pump is warrantied by the manufacturer and you must call us to determine procedures. The pump can-
not be returned to the point of purchase without our prior consent.