TROUBLE SHOOTING GUIDE CHECKLIST

NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.

Unit may be defective

Lost of prime due to a low water level
condition
Water pipe obstructed from water supply
to pump
Power cut-off by thermal protector
Pump cannot reach proper minimum
operational pressure

Loss of pressure due to leak in the piping

The water column to the highest tap
exceed 50 feet

Test electrical terminals with
voltmeter. If there is no power, replace
the unit

Wait for water level resume and press
reset button
Clean obstruction and press reset button

Wait 10 minutes and press reset button
Clogged pump nozzle and/or
venturi, clean and press reset button

Make sure all taps are closed and all toilet
valves are functionning
If leak not found, install a back valve after
the Fluomac. If cycling stops, leak is at the
supply line. If cycling occurs, leak is at
suction line. Foot valve may be defective
or clogged. Replace.

Pressure of water column is higher the
cut-in pressure (26PSI).
Re-install the unit at a higher level

TROUBLE PROBABLE CAUSE ACTION

Power supply
is on, no light
are lit.

Power supply
is on, pump on
light is off,
failure light
is on.

Power supply
is on, pump on
light is on,
failure light is
off, and pump
short cycles On
and Off.

Power supply
is on, pump on
light is on,
failure light is
off, tap is open
and no flow.
Pump is off.