Installation steps, Importante notice, Step 1 – Burcam 400500 SEWAGE PUMP 1/2HP 115V User Manual

Page 3: Step 2 step 3 step 4

Advertising
background image

3

APPLICATIONS


Designed for a permanent installation for

homes and cottages application. To pumping
where the total head requirements do not
exceed 15 feet, including pipe friction losses.



CAPACITY:

5’

4500 USGPH

17000 LPH

10’

3120 USGPH

11800 LPH

15’

720 USGPH

2700 LPH

FEATURES


Vortex designed impeller made from noryl,

will not corrode.



Rugged cast iron pump body.



Stainless steel mechanical rotary type motor

seal.



2” NPT pump discharge.



Thermal and overload protection.



1/2HP, 115VAC, 60Hz, 9.2A, (18A when start).



Mechanical type float switch, 15A.



Vertical switch for 400510 and 400500E, 10A.

INSTALLATION STEPS

See typical installation diagram in page 4

We recommend that you install your pump and basin in a clean location where there

is adequate room for servicing at a later date. Protection from freezing temperatures

and good ventilation should be considered as well, to provide the pump an

environment for long life.

Assuming that you have a sump pit located in your basement floor... Your sump pit

should be constructed from concrete, brick, tile or more recently a sump basin made

from plastic and/or fiberglass. The minimum size of your sump pit must be 18” in

diameter and no less than 25” deep. When pit is ready, proceed to next step.

Friction losses in the discharge pipe must be taken into consideration when many

elbows and fittings are installed in the discharge line. Each elbows and fittings must

be considered as 1 feet of head.

Never run the pump dry. Damage to the seal may occur.

The run of the pipe from the check valve to the existing waste or drain line must

never be slooping downward except when connecting to same.

For a new installation, install your sewage basin in the excavation you have provided

in the basement floor of your home. Connect the necessary piping from your shower

trap, toilet, etc., to the inlet of your sewage basin, with the proper pipe and fittings (see

diagram).

Cut a length of 40” to 42” of 2” ABS/DWV pipe. Cement the 2” ABS/DWV male

adaptor to 2” slip to one end of this pipe.

With your drill, make a 1/2” hole in the adaptor previously glued. This hole will prevent

any air locking wich might occur.

STEP 1

FRICTION LOSS IN

PIPE NOT INCLUDED

STEP 2

STEP 3

STEP 4

The following are minimum requirements in order to protect your residence from flooding. It is a small
investment but it is your personal responsibility to protect your home, family and valuables. Failure to
comply with the following requirements will also void your warranty:
- Two (2) pumps have to be installed in the sewage pit. The first pump as a primary pump and the

second pump as the backup unit.

- An Alarm system model 450454 has to be installed to advise you of any malfunctions.
Pump selection, proper and adequate installation are a must to comply with local by-laws and need to
be adhered to.