Trouble shooting guide checklist, Trouble probable cause action – Burcam 400500 SEWAGE PUMP 1/2HP 115V User Manual

Page 6

Advertising
background image

6

TROUBLE SHOOTING GUIDE CHECKLIST

NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE
POWER CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE
THE POWER FROM THE RECEPTACLE.

Switch is off position
Blown fuse
Tripped breaker
Disconnected plug
Corroded plug
Float stuck
Defective switch
Defective motor

Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller

Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller

Defective switch
Missing check valve
Clogged check valve in open position
Float obstruction

Turn switch to on position
Replace
Reset
Re-install
Clean
Check movement
Replace
Replace

Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 15’)
Clean

Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 15’)
Clean

Replace
Install valve
Clean debris
Check for movement

TROUBLE PROBABLE CAUSE ACTION

Motor does
not run.

Motor runs
but no water
is delivered.

Pump does
not shut off.

Pump does
not deliver to
full capacity.