TROUBLE SHOOTING GUIDE CHECKLIST

NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.

Switch is off position
Blown fuse
Tripped breaker
Disconnected plug
Corroded plug
Float stuck
Defective switch
Defective motor

Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller

Improper voltage
Pump may be airlocked
Pump discharge head too high
Clogged inlet/impeller

Defective switch
Missing check valve
Clogged check valve in open position
Float obstruction

Turn switch to on position
Replace
Reset
Re-install
Clean
Check movement
Replace
Replace

Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 25’)
Clean

Check voltage
Check drilled hole in discharge pipe
Wrong pump selection (over 25’)
Clean

Replace
Install valve
Clean debris
Check for movement

TROUBLE PROBABLE CAUSE ACTION

Motor does not
run.

Motor runs but
no water is
delivered.

Pump does not
shut off.

Pump does not
deliver to full
capacity.

TO THE END CONSUMER

If you have any problems with the product, before advising the store, where you’ve
purchased the pump, please contact us at 514 337-4415 , and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.