APPLICATIONS

This system is designed with an automatic pump

for a permanent installation to evacuate

domestic waste water from a sink to an existing
drain pipe.

Can be used in light commercial application.

CAPACITY:

5’

2500 US GPH

10’

2100 US GPH

15’

1550 US GPH

18’

550 US GPH

FEATURES

High performance noryl impeller.

Vertical automatic switch.

Full time connected run capacitor, to eliminate

starting wear vs regular motor.

Thermal and overload protection.

1/4HP, 115VAC, 60Hz, 3.0A (7.5A when start.)

INSTALLATION STEPS

see typical installation diagram in page 4

We recommend that you install your pump in a clean and dry location where there is
adequate room for servicing at a later date. Protection from freezing temperatures and good
ventilation should be considered as well, to provide the pump an environment for long life.
Do not use to pump gas or toxic fuels. This submersible sump pump is designed to pump
water only
. Locate the pump directly under the sink (see page 4).

Friction losses in the discharge pipe must be taken into consideration when the horizontal off-
set is greater than 50 feet. The discharge pipe should be increased from 1 1/2” to 2”. This
will reduce friction losses and allow the pump to give maximum performance.

More friction losses must also be taken into consideration when many elbows and fittings are
installed in the discharge line. Each elbows and fittings must be considered as 1 feet of head.

The float switch of your pump has been pre-set at the factory and does not need any adjust-
ment. Teflon tape is required for all treaded connection.

Never run the pump dry. Damage to the seal may occur.

THE RUN OF THE PIPE FROM THE CHECK VALVE TO THE EXISTING WASTE OR
DRAIN LINE MUST NEVER BE SLOOPING DOWNWARD EXCEPT WHEN CONNECTING
TO SAME.

Using 1½” pipes and fittings, connect the sink strainer to the basin intake (a P-trap is required
between the strainer and the basin).

Using 1½” pipes and fittings, connect the pump discharge to the closest existing drain line.
Install a check valve in vertical position (350362) on the discharge pipe of the pump.

Using 1½” pipes and fittings, connect the vent line from the basin lid to the house plumbing
vent line.

Connect the power cables to the electric outlet previously installed.

STEP 1

FRICTION LOSS IN

PIPE NOT INCLUDED

STEP 2

STEP 3

STEP 4
STEP 5

3

FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029