Trouble shooting guide checklist, Trouble probable cause action – Burcam 300319B 12 SINK PUMP SYSTEM 1/4HP 115V 60HZ User Manual

Page 5

Advertising
background image

FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029

5

TROUBLE SHOOTING GUIDE CHECKLIST

NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.

Switch is off position
Blown fuse
Tripped breaker
Switch port clogged
Defective switch
Defective motor

Improper voltage

Improper voltage

Defective switch
Missing check valve
Clogged check valve in open position

Defective switch
Pump discharge too fast on low head

Water pumped faster than tub is filled

Turn switch to on position
Replace
Reset
Remove and clean switch, port, adaptor
Replace
Replace

Check voltage

Check voltage

Replace
Install valve
Clean debris

Replace
Install ball valve in discharge line to
reduce flow rate
It is normal

TROUBLE PROBABLE CAUSE ACTION

Motor does not
run.

Motor runs but
no water is
delivered.

Pump does not
shut off.

Pump does not
deliver to full
capacity.

Pump starts and
stop too often.

TO THE END CONSUMER

If you have any problems with the product, before advising the store, where you’ve
purchased the pump, please contact us at 514 337-4415 , and ask for our sales
department, and they will be pleased to help you with any questions you might have,
concerning your installation.

Advertising