Installation steps, Step 1, Step 2 – Burcam 300722 1/2HP 115V EFFLUENT PUMP VERTICAL SWITCH 20 User Manual

Page 3: Important notice

Advertising
background image

3

APPLICATION
 This submersible effluent pump is designed for

a permanent installation for domestic use
homes, cottages and farms.

Multi-purpose effluent pump will fill the need in

most sump applications.

To pump dirty water as a permanent

installation pump.

Can also be used as a fountain pump.
Ideal as a utility pump to transfer water.
 CAPACITY:

10’ 10800 US GPH
30’ 8200 US GPH
50’ 4800 US GPH

INSTALLATION STEPS

We recommend that you install your pump in a clean location where there is adequate room
for servicing at a later date. Protection from freezing temperatures and good ventilation
should be considered as well, to provide the pump an environment for long life. Do not
use to pump gas or toxic fuels. This submersible sump pump is designed to pump
water only
.

Friction losses in the discharge pipe must be taken into consideration when the horizontal off-
set is greater than 50 feet. The discharge pipe should be increased from 1 1/2” to 2”. This
will reduce friction losses and allow the pump to give maximum performance.

More friction losses must also be taken into consideration when many elbows and fittings are
installed in the discharge line. Each elbows and fittings must be considered as 1 feet of head.

The float switch of your pump has been pre-set at the factory and does not need any adjustment.

Never run the pump dry. Damage to the seal may occur. Fill pump pit or sump basin with
water before turning on the power.

Assuming that you have a sump pit located in your basement floor... Your sump pit may be
constructed from concrete, brick, tile or more recently a sump basin made from plastic and/or
fiberglass. The minimum size of your sump pit should be 18” in diameter and no less than
25” deep. When pit is ready, proceed to next step.

STEP 1

FRICTION LOSS

IN PIPE NOT

INCLUDED

STEP 2

FEATURES
 Non corrosive material.
 Cast iron motor body.
 Stainless steel mechanical rotary seal.
 Thermal and overload protection.
 Piggy back grounded cables
 1/2HP, 115V AC, 60Hz, 5A, (10A when start).

IMPORTANT NOTICE

Please note before you proceed with the installation of this product that
the manufacturer's guideline has to be respected. Failure to comply may
void your warranty.

The following are minimum requirements in order to protect your residence from flooding. It is a small
investment but it is your personal responsibility to protect your home, family and valuables. Failure to comply
with the following requirements may also void your warranty:

- Two (2) pumps have to be installed in the sump pit. The first pump as a primary pump and the second pump
as the backup unit.

- Burcam alarm system model 450454 has to be installed to advise you of any malfunctions.

- As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery powered
back up pump model 300403 has to be installed to evacuate the water.

Pump selection, proper and adequate installation are a must to comply with local by-laws and need to be
adhered to.