Repair parts effluent pump application, Step 2, Step 3 – Burcam 300722 1/2HP 115V EFFLUENT PUMP VERTICAL SWITCH 20 User Manual

Page 5: Step 4, Step 6, Step 7, Step 8, Step 5, Bur-cam pumps

Advertising
background image

5

Repair parts may be ordered from your authorized point of sale or from

BUR-CAM PUMPS

STEP 2

Sump pit 18” diameter
X 25” depth

STEP 3

Prepare your choice
of discharge pipe size
and check valve

STEP 4

Install your pump in
centre of pit

STEP 6

Connect float and
motor power cable

STEP 7

Fill the basin and
test the operation

STEP 8

Review and check
connections for
leaks

REPAIR PARTS

EFFLUENT PUMP APPLICATION

REF PIECES

DESCRIPTION

1

310206

Power Cord

2

310207

Top Cover

3

310208

Capacitor

9

310209

Mechanical Seal

10

310210

Seal Plate

11

310211

Oil Seal Cover

12

310212

Oil seal

13

310213

Upper Impeller

14

310214

Lower Impeller

15

310215

Upper Pump Casing

REF PIECES

DESCRIPTION

16

310216

Lower Pump Casing

17

310217

Sleeve

18

310218

“O”-ring

19

310219 “O”-ring

20

310220

Packing

21

310221

Screw

22

310222

Bolt

23

310223

Strainer

24

310224

Base

25

450447

AG

Vertical Float Switch

STEP 5

Install discharge pipe

Advertising