Fitting the torrium2, Directly to the pump – Davey HP/T & HS/T Pressure Systems with Torrium2 User Manual

Page 3

Advertising
background image

3

NOTE: The Torrium2

®

controller fitted to this pump is adaptive. If your

pump draws air or is subject to blockage, the Torrium2 adapts to its new

maximum pressure. This may result in your system pressure not dropping

below the new cut-in pressure and your pump not starting. Should this

occur, re-prime your pump units as detailed above. Should this not prove

successful, it is likely you have a blockage in the pump. You should

contact your Davey dealer for assistance.

Rotary Coupling Inlet

1” Male

Horizontal Outlet

1” Male

Priming Cap which covers the 1” Male Vertical Outlet

and access to the internal check valve.

Status Indicator

Lights

Prime Button

Pressure

Indicator

Window

Fitting the Torrium2

®

directly to the Pump

The Torrium2

®

is fitted with a rotary coupling. This

coupling allows the pump controller to be fitted

simply and easily to the pump discharge.

The coupling has an oring seal. The controller

adaptor nut is able to rotate independent of the

Torrium2

®

and the complete pump, this allows it

to be tightened onto the pump easily. For ease

of installation a tightening tool is included with

Torrium2

®

to tighten the controller nut to ensure a

firm connection to your controller.

The ability to rotate the adaptor nut also means that the complete controller, once

fitted to the pump, can be rotated a full 360

o

in the horizontal plane, without causing

the coupling to unscrew from the pump outlet.

With Torrium2

®

you can connect the discharge pipework to the

discharge port and/or the vertical priming port. The priming port is

able to be used as a discharge port.

WARNING: When servicing or attending pump, always ensure power

is switched off and lead unplugged. Electrical connections should be

serviced only by qualified persons. If the electrical supply lead of this

pressure system is damaged, it must be replaced.

NOTE:

a) For protection, the Davey

®

pump motor is fitted with an automatic

“over temperature” cut-out. Constant tripping of this overload device

indicates a problem e.g. low voltage at pump, excessive ambient

temperature (above 50°C) in pump enclosure.

b) The Torrium2

®

control device may have to be reset after rectifying any

of the above operating troubles. This is done by pushing in the “prime”

button and releasing it after 2 seconds, or switching the power supply

off then on.

Care should also be taken when servicing or disassembling pump to avoid

possible injury from pressurised water. Unplug pump, relieve pressure by

opening a tap on the discharge side of the pump and allow any hot water in

the pump to cool before attempting to dismantle.

During servicing, use only approved, non-petrochemical based oring and

gasket lubrication. If unsure, consult your Davey Dealer for advice.

WARNING: Do not use hydrocarbon based or hydrocarbon propelled

sprays around the electrical components of this pump.

In accordance with AS/NZS 60335.2.41 we are obliged to inform you that

this pump is not to be used by children or infirm persons and must not be

used as a toy by children.

NOTE: The Torrium2

®

controller is adaptive. If your pump draws air or is subject to

blockage, the Torrium2

®

adapts to its new maximum pressure. This may result in

your system pressure not dropping below the new cut-in pressure and your pump

not starting. This is more likely to occur when boosting mains pressure. Should this

occur, re-prime your pump unit. Should this not prove successful, it is likely you have

a blockage in the pump. You should contact your Davey dealer for assistance.