Starting, Structural representation, Trouble shooting – Davey ISOSPEC CF Series ISO2858 Heavy Duty Industrial Centrifugal Pump User Manual

Page 3: Lubrication

Advertising
background image

~ 3 ~

Starting

Caution: Do not attempt to run pump if it

has not been filled with water ( primed).

Severe damage will result to shaft seal.

1) Ensure the suction line & pump casing is full of water

open suction valve if fitted.

2) Check power is off & rotate the pump shaft slowly to

release any trapped air within the pump casing.

3) Close the discharge valve.
4) Check the direction of rotation on the pump casing or

motor cover.

5) If this is correct you may now start the pump, when

it reaches full speed you will see the pressure in the

discharge line rise. Slowly open the discharge valve

until the pump adjusts to maintain its duty point.

Structural Representation

1. Bearing housing

2. Shaft

3. Rear casing cover

4. Pump casing

5. Impeller

6. Impeller key

7. Impeller washer

8. Impeller nut

9. Volute drain plug

10. Bronze wear ring

11. Mechanical shaft seal

12. Bearing housing foot

13. Bearing lip seal

14. Bearing

15. Bearing cap

16. Water slinger

Trouble Shooting

Pump is running but failing to deliver water or

desired pressure.

1)

Turn the unit off.

2)

Check suction line is free of debris or blockages

& check that the pump has not lost its prime. If

so, remove blockage & repeat Starting at step 1).

3)

Check that the suction valve is open.

4)

Check that the discharge valve is open.

5)

Check for air leaks. These may not always be

visible to the naked eye unless pressure is applied

to the suction line.

6)

Check that the suction line is not too long.

7)

Is suction line to pump excessive?

8)

Is the foot valve stuck open or undersized?

9)

Is speed too slow?

10) Check motor direction rotation.

11) Check for possible clogging in impeller vanes

12) Is the discharge piping undersized for

applications.

Excessive Vibration
1)

Turn unit off

2)

Check motor is rotating in correct direction

3)

Check both motor feet & pump feet are secured

properly.

4)

Check coupling rubbers are not worn

5)

Check drive couplings are secured tightly to the

pump & drive shafts.

6)

Check pump & motor bearings are OK

7)

If so, alignment will need to be performed

8)

Impeller could be partially blocked causing

imbalance

Noisy Operation
1)

Turn unit off

2)

Check pump or motor bearings

3)

Check pump is primed

4)

Check suction line is not damaged causing

insufficient supply & resulting in cavitation

5)

Check you are not pumping solids

High Power Consumption

1)

Check direction of rotation

2)

Check operating speed on the motor matches the

intended performance curve speed.

3)

Check that the estimated head is correct as pump

may be running down on its curve producing high

flow but drawing more power. Throttle the pump

back on to its curve via discharge gate valve or

reduce impeller diameter.

4)

The Specific Gravity or Density of the liquid is

greater than 1kg/litre affecting power draw.

5)

Check impeller diameter for the correct size to

establish maximum power requirement at duty

point.

Lubrication

Pump bearings are greased for life.

Motor bearings refer to Motor manufacturers

recommendations.

In accordance with AS 3350.2.41 we are obliged

to inform you that this pump is not to be used by

children or infirm persons and must not be used

as a toy by children.