Introduction

Thank you for purchasing a quality Davey product. It is

our commitment to satisfy our customers by offering our

very best service.

This manual contains instruction for installation,

operation and maintenance of ISOspec

®

CM series

of single stage, non-self priming, centrifugal pumps.

Therefore, please read it carefully before use to obtain a

long satisfying service life of the purchased unit.

Davey ISOspec

®

CM series centrifugal pumps are

designed with high efficiency and low maintenance

features.

Specifications

Model designation (example) :-

CM 125×100-200

Nominal dia. of impeller (mm)

Dia. of outlet (mm)

Dia. of inlet (mm)

Series code of pump

Inspection of Pump

Always check on receipt of delivery you have

received the correct pump unit. To identify, see above

specifications and label below. Check correct motor kW

& speed on motor nameplate (attached to motor) prior to

installation.

Delivery

Upon receipt the unit should be thoroughly inspected for

any damage sustained during transit. Any equipment

damage or shortfall should be immediately advised to

your nearest Davey office or Davey customer service

centre.

Storage

If the unit is not to be installed immediately, it should be

stored in a clean, dry and preferably warm environment.

Shafts of stored motors should be rotated occasionally.

Specific vibration during storage may lead to “brinelling”

of the bearings, therefore motors that are subject to

extended storage where vibration exists, should be fitted

with bearing locks.

Installation Location

It is important to select a site as close to the liquid

source as possible. When a suction lift is unavoidable,

install the pump as near to the water level as possible

(see suction piping). You should always check

the maximum permissible lift of the pump from its

performance curve.

Foundations

The pump unit should be mounted on a foundation that

is substantial enough to withstand the weight of the unit

& large enough to accommodate all mounting feet so

they can be securely fixed to avoid movement.

Suction Piping

All fittings & suction piping should be free of air leaks.

When a suction lift or long suction lengths are

unavoidable, consideration should be given to over

sizing the suction line to reduce suction losses.

On suction lifts a foot valve will be required, sized equal

to the suction line size. For applications on creek beds

or dams, please install a foot valve & strainer, well

submerged below the surface, to reduce whirlpools & air

inclusion. Air inclusion can result in cavitation reducing

the pump performance & eventually destroying the pump

or its components.

If bends are required, long radius bends should be used.

To help ensure a less turbulent entry into the pump,

a straight length of pipe should be installed between

any bends and the pump inlet. This straight length

should be at least 2.5 times the pump inlet diameter in

length. Pipework supports should be installed to both

inlet and outlet pipes to ensure that they are supported

independently of the pump flanges.

Discharge Piping

Discharge piping must be selected of a size that would

equal the discharge of the pump. For long discharge

lengths, consideration should be given to using larger

diameter pipework. Larger size pipes have lower

pressure losses for a given flow rate, and may help

reduce the running costs for your pumping system.

Talk to your nearest Davey dealer to calculate all system

losses. To avoid air pockets in discharge lines at high

points, vent cocks may be required to release air blocks

accumulated within the system. Air pockets may affect

the performance of the pump. A throttling valve should

be installed in the discharge line to ensure the pump

works within the performance curve.