Davey X90 Water Pressure Systems User Manual

Page 2

Advertising
background image

Choosing a Site

Choose a site with a firm base and as close

to the water source as possible with correct

power supply. Make sure your pressure

system is always connected to an adequate,

reliable source of clean water.

Housing your Davey Pressure System

To protect your pressure system from the weather,

make sure the pump house is both water proof,

frost free and has adequate ventilation. The pump

should be horizontally mounted on a firm base

allowing for drainage, to avoid damage to flooring

etc., that over time may occur from leaking pipe

joints or pump seals. Do not mount the pump

vertically.

A good quality non-return valve must be

installed in the pressure pump outlet pipework

before the hot water service. Failure to install

this non-return valve may result in pump

damage. Such damage is not covered by

guarantee.

Connection of Mains Scheme or Town Water Supply to either Suction or

Discharge of Pumps & Pressure Systems

Most Water Supply Authorities have strict regulations regarding direct

connection of pumps to mains water supplies. In most cases an isolating tank

is required between mains supply and pump. Davey also recommend this

method. Directly applied mains pressure can exceed pump operating pressure

and damage pump.

Davey Products Pty Ltd can

not accept responsibility

for loss or damage

resulting from incorrect or

unauthorised installations.

WARNING: Some insects, such as small ants, find electrical devices

attractive for various reasons. If your pump enclosure is susceptible

to insect infestation you should implement a suitable pest control plan.

Pipe Connections

For best performance use P.V.C. or polythene pipes at least the same

diameter as the pump’s inlet and delivery outlet openings. Larger diameter

pipe may be used to minimise resistance to flow when pumping longer

distances.

Use unions at pipe connections to enable easy removal and servicing. Use

sufficient tape to ensure airtight seal and hand tighten only. To prevent strain

on pump threads always support heavy inlet and outlet pipes. If there is a

likelihood the water supply may contain

solid particles such as pieces of plant or

vegetable matter, a suction strainer should

be installed before the pump to avoid

blocking of the pump. Lay suction pipe at

a constant gradient to avoid air pockets

which may reduce pump efficiency.

Where to use Check Valves and Foot Valves

Installations with a suction lift over 1m require a good quality foot valve to

avoid loss of prime. In this case, the poppet valve inside the pump should

be removed. Installations with flooded suction require a gate valve so water

supply can be turned off for pump removal and servicing.

Prior to using this pump you must ensure that:

• The pump is installed in a safe and dry environment

• The pump enclosure has adequate drainage in the event of leakage

• Any transport plugs are removed

• The pipe-work is correctly sealed and supported

• The pump is primed correctly

• The power supply is correctly connected

• All steps have been taken for safe operation

Appropriate details for all of these items are contained in the following

Installation and Operating Instructions. Read these in their entirety before

switching on this pump. If you are uncertain as to any of these Installation and

Operating Instructions please contact your Davey dealer or the appropriate

Davey office as listed on the back of this document.

Congratulations on your purchase of a high quality, Australian built Davey pres-

sure system. All components have been designed and manufactured to give

trouble free, reliable operation.

1. Pressure tank

2. Pressure switch

3. Delivery outlet

4. Suction inlet

5. Pump body

6. Motor

7. Base

8. Priming plug

Connection sizes:

Model Inlet Outlet

X50

1”

1”

X70

1

1

/

4

1”

X90

1

1

/

4

1”

Do not use pipe thread sealing compounds on any part of this pump.

ONLY use Teflon sealing tape.

Before installing your new pump, please read all instructions carefully as fail-

ures caused by incorrect installation or operation are not covered by the guar-

antee. Your Dynajet® system is designed to handle clean water. It should not

be used for any other purpose without specific referral to Davey. The use of the

pump to handle flammable, corrosive and other materials of a hazardous nature

is specifically excluded.

Priming and Operation

1. Remove priming plug and fill

pump and suction line (on flooded

suction, simply open gate valve

to pump). When full,

replace priming plug.

2. Ensure outlet nearest to pump is

open.

3. Ensure all valves in suction line are

open and switch on.

4. Prime should establish almost

immediately and a strong flow

of water should be

evident from the

outlet. Allow water to

flow for 10-20 seconds

to expel air then close

outlet.

5. If no flow is evident from tap,

switch off at power point and repeat

from step 1 ensuring there is an

adequate supply of water available

to the pump.

Power Connection

Connect lead to power supply designated on pump label, do not use

long extension leads as they cause substantial voltage drop, poor

pump performance and may cause motor overload.

NOTE: Suction leaks are the

largest cause of poor pump

performance and are difficult

to detect. Ensure all

connections are completely

sealed using thread tape only.

IMPORTANT

For Automatic Pressure Pumps Installed with a Mains Pressure Hot

Water System.

Abrasive Materials

The pumping of abrasive materials will cause damage to the

pressure system which will then not be covered by the guarantee.