3

Pressure Switch Setting and Tank Precharge

Your Davey HM Series Pressure Pump should have the correct pressure

switch settings for zero suction lift. If your pump is installed with a suction

lift you may need to have the cut out switch settings adjusted. The

pressure tank(s) fitted must be air pre-charged as per the table in the

maintenance section of these instructions.

Choosing a Site

Choose a site with a firm base and as close to the water source as

possible with correct power supply. Make sure your pressure system is

always connected to an adequate, reliable source of clean water.

Housing your Davey Pressure System

To protect your pressure system from the

weather, make sure the pump house is both

water proof, frost free and has adequate

ventilation. The pump should be horizontally

mounted on a firm base allowing for drainage,

to avoid damage to flooring etc., that over time

may occur from leaking pipe joints or pump seals.

Do not mount the pump vertically. Never place

flammable materials on or near your pump.

Power Connection

Connect lead to power supply designated on pump label. Do not use

long extension leads as they cause substantial voltage drop, poor pump

performance and may cause motor overload.

WARNING: Some insects, such as small ants, find electrical devices

attractive for various reasons. If your pump enclosure is susceptible to

insect infestation you should implement a suitable pest control plan.

The electrical connections and checks must be made by a qualified

electrician and comply with applicable local standards. Poor installation

or poor power supply may even result in electrical fires!

WARNING: When servicing or attending pump, always ensure power

is switched off and lead unplugged. Electrical connections should be

serviced only by qualified persons. If the electrical supply lead of this

pressure system is damaged, it must be replaced.

Care should also be taken when servicing or disassembling pump to avoid

possible injury from pressurised water. Unplug pump, relieve pressure by

opening a tap on the discharge side of the pump and allow any hot water in

the pump to cool before attempting to dismantle.

During servicing, use only approved, non-petrochemical based oring and

gasket lubrication. If unsure, consult your Davey Dealer for advice.

WARNING: Do not use hydrocarbon based or hydrocarbon propelled

sprays around the electrical components of this pump.

NOTE: For protection, the Davey

®

pump motor is fitted with an automatic

“over temperature” cut-out. Constant tripping of this overload device

indicates a problem e.g. low voltage at pump, excessive ambient

temperature (above 50°C) in pump enclosure.

WARNING: Automatic reset thermal overloads will allow the pump to restart

without warning. ALWAYS disconnect the pump motor from the electrical

supply before maintenance or repairs.

WARNING: Do not use hydrocarbon based or hydrocarbon propelled sprays

around the electrical components of this pump.

In accordance with AS 3350.2.41 we are obliged to inform you that this

pump is not to be used by children or infirm persons and must not be used

as a toy by children.