Connection to your water source, Choosing a site, Housing your davey pressure system – Davey XJ50/XJ70/XJ90 Electric Pumps User Manual

Page 2: Pipe connections, Where to use check valves and foot valves, Power connection, Important

Advertising
background image

A good quality non-return valve must be installed

in the pressure pump outlet pipework before the

hot water service. Failure to install this non-return

valve may result in pump damage. Such damage

is not covered by guarantee.

Connection of Mains Scheme or Town Wa-

ter Supply to either Suction or Discharge of

Pumps & Pressure Systems

Most Water Supply Authorities have strict regu-

lations regarding direct connection of pumps to

mains water supplies. In most cases an isolating

tank is required between mains supply and pump. Davey also recommend this

method. Directly applied mains pressure can exceed pump operating pressure

and damage pump.

Davey Water Products

Pty Ltd can not accept

responsibility for loss or

damage resulting from

incorrect or unauthorised

installations.

Connection to your Water Source

BELOW GROUND WATER SOURCES

Whenever the installation position of the pump is higher than 1m (3.3ft) above

the lowest water level, a foot valve must be used on the end of the suction pipe

as illustrated in (C) below. Ensure that the foot valve is at least

1

/

2

metre below

minimum water level.

SPEAR POINT INSTALLATIONS

When a Dynajet

®

is installed on a spear or well point, a check valve must be

fitted immediately on top of the spear point itself, as shown in (D) above.

DO

NOT INSTALL THE CHECK VALVE AT THE PUMP OR AT THE TOP OF THE

WELL. DO NOT RUN THE PUMP WITHOUT WATER.

NOTE: Be certain to select the spear point to suit the well conditions and

regulate the flow rate from the pump accordingly.

SPEAR SIZE

MESH

APPROX. MAX. CAPACITY OF SPEAR

POINT

1

1

/

4

” (32mm)

60

15 - 23 1/min or 200 - 300 gal/hr

1

1

/

2

” (38mm)

60

23 - 38 1/min or 300 - 500 gal/hr

2” (50mm)

60

38 - 75 1/min or 500 - 1000 gal/hr

WARNING: Some insects, such as small ants, find electrical devices

attractive for various reasons. If your pump enclosure is susceptible

to insect infestation you should implement a suitable pest control plan.

Choosing a Site

Choose a site with a firm base and as close

to the water source as possible with correct

power supply. Make sure your pressure

system is always connected to an adequate,

reliable source of clean water.

Housing your Davey Pressure System

To protect your pressure system from the weather,

make sure the pump house is both water proof,

frost free and has adequate ventilation. The pump

should be horizontally mounted on a firm base

allowing for drainage, to avoid damage to flooring

etc., that over time may occur from leaking pipe

joints or pump seals. Do not mount the pump

vertically.

Pipe Connections

For best performance use P.V.C. or polythene pipes at least the same

diameter as the pump’s inlet and delivery outlet openings. Larger diameter

pipe may be used to minimise resistance to flow when pumping longer

distances.

Use unions at pipe connections to enable easy removal and servicing. Use

sufficient tape to ensure airtight seal and hand tighten only. To prevent strain

on pump threads always support heavy inlet and outlet pipes. If there is a

likelihood the water supply may contain solid particles such as pieces of plant

or vegetable matter, a suction strainer

should be installed before the pump to

avoid blocking of the pump. Lay suction

pipe at a constant gradient to avoid

air pockets which may reduce pump

efficiency.

Where to use Check Valves and Foot Valves

Installations with a suction lift over 1m require

a good quality foot valve to avoid loss of prime.

In this case, the poppet valve inside the pump

should be removed. Installations with flooded

suction require a gate valve so water supply can

be turned off for pump removal and servicing.

Prior to using this pump you must ensure that:

• The pump is installed in a safe and dry environment

• The pump enclosure has adequate drainage in the event of leakage

• Any transport plugs are removed

• The pipe-work is correctly sealed and supported

• The pump is primed correctly

• The power supply is correctly connected

• All steps have been taken for safe operation

Appropriate details for all of these items are contained in the following Installation and

Operating Instructions. Read these in their entirety before switching on this pump. If you

are uncertain as to any of these Installation and Operating Instructions please contact

your Davey dealer or the appropriate Davey office as listed on the back of this document.

Congratulations on your purchase of a high quality, Australian built Davey pressure

pump. All components have been designed and manufactured to give trouble free,

reliable operation.

XJ Ultra / XJ70P / XJ90P

1. Pressure tank

(supplied separately)

2. Pressure switch

3. Delivery outlet (1”F)

4. Suction inlet

(XJ Ultra = 1”F)

(XJ70P & XJ90P = 1

1

/

4

”F)

5. Pump body

6. Motor

XJ50 / XJ70 / XJ90

Are the same as above

less items 1 & 2.

Note: Your XJ Ultra, XJ70P &

XJ90P pump is designed to oper-

ate as an automatic pressure sys-

tem when used in conjunction with

a pressure tank such as a Davey

“Supercell 18C” tank (illustrated).

The tank, supplied separately,

needs to be fitted to the delivery

outlet prior to operating.

Assembly

Attach pressure switch (2)

to the delivery outlet tee (3)

by hand tightening the pres-

sure switch union nut (ensure

sealing oring is in place).

Screw pressure tank (1) onto

delivery outlet.

Power Connection

Connect lead to power supply designated on pump label, do not use

long extension leads as they cause substantial voltage drop, poor

pump performance and may cause motor overload.

Before installing your new pump, please read all instructions carefully as failures caused

by incorrect installation or operation are not covered by the guarantee. Your Dynajet®

XJ pump is designed to handle clean water. It should not be used for any other purpose

without specific referral to Davey. The use of the pump to handle flammable, corrosive

and other materials of a hazardous nature is specifically excluded.

Do not use this pump to pump flammable fluids, such as petrol or

diesel fuels.

Do not use pipe thread sealing compounds on any part of this pump.

ONLY use Teflon sealing tape.

NOTE: Suction leaks are the

largest cause of poor pump

performance and are difficult

to detect. Ensure all

connections are completely

sealed using thread tape only.

IMPORTANT

For Automatic Pressure Pumps Installed with a Mains Pressure Hot

Water System.

Abrasive Materials

The pumping of abrasive materials will cause damage to the

pressure system which will then not be covered by the guarantee.

Spear point flow capacities vary considerably. Check with the supplier

to ensure the pump and spear point are correctly matched.