Location of the pressure regulator – Davey Hurricane Turbo Swim Jet User Manual

Page 4

Advertising
background image

4

LOCATION OF THE PRESSURE REGULATOR:

If your electrical equipment box is more than 5 metres away from the front face, you should
bring the pressure regulator (interrupter of the pneumatic button) close to the swimming pool in
a connection box.

POSITIONING OF THE PUMP:

The pump of this device must be installed next to the structure and must be connected by a
pressure pipe, minimum diameter 50mm.
If this is not possible the pump can be placed further away, although the loss of pressure/flow
must be calculated for. Refer Table below.

Distance between the front face and the pump

Diameter of the pipes

1m

Diameter 50mm (2”)

1 to 5 m

Diameter 65mm (2.5”)

5 to 15 m

Diameter 80mm (3”)

PACKAGE NO.2

Additional components:

Ergonomic Jet Face.
Adjustable Air Outlet Valve.
Pneumatic Start-Up Control.

PACKAGE NO.3

Single-phase or Three-phase Hydro-Electric Generating Set.

PACKAGE NO.4

Single-phase or Three-phase Switch Box (with Thermal Relay adapted in accordance to the
choice of Hydro-Electric Generating Set).