Installation instructions for chloromatic, Esr and esc) – Davey MCxxC CHLOROMATIC Salt Water Pool System User Manual

Page 4

Advertising
background image

4

• Page 3 •

INSTALLATION INSTRUCTIONS FOR CHLOROMATIC

®

(ESR and ESC)

Note: For ESCpH models, please read all instructions then refer to page 15-17 for more information.

INSTALLING THE POWER SUPPLY:
Select a convenient well-ventilated location within one metre of filter equipment and mount the Power Supply
vertically onto a post or wall 1.5 metres above ground level. Australian Standards requires that the Power
Supply shall not be located within 3 meters of the pool water. Plug Power supply into a suitable weatherproof
outlet and plug pump into the power outlet of the Power Supply Unit. The Unit must be kept away from acid
and other chemical storage areas. Acid and chemical vapours will corrode the electronics inside the Unit. It
must also be kept away from heat sources. Good ventilation is necessary for correct operation.

Two self-tapping screws and wall plugs have been provided for fast and simple installation. Simply cut out
Template at bottom of page 19 for location of drill entry points. Use a 7mm masonry drill bit when fitting
Power Supply to a brick or concrete wall. When mounting to a post drill pilot holes and fit screws provided.
Once screws are in position simply hang chlorinator via bracket on back of Unit.

Flow

Flow

IMPORTANT:
This diagram is intended to conform with S.P.A.S.A.
for the safe operation of saline chlorinators. Any
deviation is at the installers risk and may void the
manufacturers warranty.

NOTE:
The cell must be fitted to allow for easy removal and
cleaning, and positioned after all accesories such as
heater or pool cleaner, but before it divides if there is
more than one return to pool line.

Note: The Chlorinator is not intended for use by young children or infirm persons without

supervision. Please ensure that young children are supervised to ensure that they do not play

with the Chlorinator.

Power connections and wiring must be carried out by an authorised electrician.

Example of