Control panel layout – Davey MCxxC CHLOROMATIC Salt Water Pool System User Manual

Page 6

Advertising
background image

6

• Page 5 •

Once the salt level in the pool is correct the unit may be switched on. Set Sanitiser Output to Max (100%).
The STAND - BY indicator will be On and no Cell Output will be seen for approx 30 seconds, this allows the
pump and filter to prime and the Cell Housing to fill with water. After this start - up delay, the display should
show 100 (ESR Models (+/-2), unless in Winter Mode where it will display 85 (ESR Models (+/-2). At this
point both Operation LED’s should be Green; if not there may be a problem. (Refer table).

DISPLAY / INDICATOR

LED 1

LED 2

REASON / ACTION

STAND – BY ON

Green

Green

1. Start-up delay functioning.
2. Sanitiser Output set below max.
Cell is turned off. (Refer Sanitiser Output
page 7)

FLOW
STAND – BY
ON

Green

Green

1. Gas detected. Check pump/pipes for damage
2. Gas sensor not connected to cell.

FLUCTUATING
AROUND 100

Green

Green

System operating normally.

Green

Red

1. Salt level too low. Add salt at a rate of 25kg
per 25,000L.
2. Cell is calcified. Clean cell.
3. Water temperature low. Switch to Winter
Mode.

Red

Red

1. Salt level below minimum. Add Salt.
2. Cell is calcified. Clean cell.
3. Water temperature very cold. Switch to
Winter Mode. Continued operation may
cause damage to system – Consult dealer for
problem rectification.

PLEASE NOTE: When Winter Mode switch is On Unit will operate similar to above except Display will

fluctuate around 85. (Refer Winter Mode page 8).

AM

6

CONTROL PANEL LAYOUT

OPTIONAL POOL LIGHT
SWITCH

SELECTOR SWITCH

TIME CLOCK

SANITISER OUTPUT DIAL

WINTER MODE SWITCH

OPERATION LED’S

Advertising
This manual is related to the following products: