Pre - start up procedure, Operation of your chloromatic, System – Davey MCxxC CHLOROMATIC Salt Water Pool System User Manual

Page 5

Advertising
background image

5

• Page 4 •

CONNECTING THE ELECTROLYTIC CELL TO THE POWER SUPPLY:
The Power Supply is fitted with a flexible lead terminated with brass connectors. These must be correctly
fitted to the connections on the inside of the Cell Head. To prevent incorrect connection the fittings have been
colour coded.

ESR

Black to Black & White to White

ESC /

ESCpH

Either Black Terminal

The Blue Gas Sensor connector should be pushed onto the thread of the small bolt. The power outlet on the
bottom of the Power Supply is dedicated to the POOL PUMP ONLY.

Important: The Cell must be installed so that the water flows through the Cell Housing via the Cell head end
in accordance with the arrow on the cell housing. This is to ensure correct operation of the gas sensor.

PRE - START UP PROCEDURE:

Before operating your ChloroMatic® please ensure the following items have been added to your pool:

SALT - Load salt into the pool at the following rates:

• All ChloroMatic Models – Around 45-60kg per 10,000 litres (4500-6000ppm)

Connect manual vacuum system and slowly vacuum until salt dispersal is complete. Place vacuum head into
deepest end of pool and allow vacuum to continue for a further 2 or 3 hours. Salt should now be completely
mixed. Never add salt directly into skimmer box.

CHLORINE - For a new pool installation that has not been chlorinated, add sufficient Chlorine (liquid or
granular) to achieve a reading of 3 ppm (with a suitable test kit), or run the chlorinator system continuously
for at least 24 hours or until a reading of 3 ppm is reached.

STABILISER - It is essential that pool stabiliser be added and maintained at the rate of 30 - 50 ppm at all
times. Do not exceed 100 ppm.

(Refer Day to Day Operation page 12 for further information).

OPERATION OF YOUR ChloroMatic

®

SYSTEM:

Cell Output on the digital LED display is expressed as a percentage. The Display will fluctuate around 100
when producing sanitiser - unless in Winter Mode, in which case the Display will fluctuate around 85. (Refer
Winter Mode page 8). The Unit is fitted with an electronic control and warning system. This regulates the
output of the Unit to the preset maximum. The warning system consists of two Operation LED’s that will glow
Green, or Red to indicate possible faults with the Unit or damaging operating conditions.

Do not use a double adaptor to connect more than one pump - it can cause overload to the system

and could void your warranty. *Does not relate to MCS50C.

Advertising
This manual is related to the following products: