Mounting instructions

49

English

Completing electrical connections, ill. 9

Lay all cables carefully. Refer to the connecting diagram on the fold-out page at the
end of this booklet and to the table below.

Power supply cable

2 (ISO connector A):

● = connection required
❍ = connection optional

A

A

A

A

Only connect electrical signals to appropriate terminals in the

vehicle.

A

A

A

A

In the case of a direct connection to the battery secure the

positive connection (red lead) with a 10 A fuse close to the battery
(max. 4 - 6 inches).

1. Connect the free cable ends A4, A7 and A8 of the power supply cable

2 to

suitable terminals in the vehicle according to the connecting diagram and the
table.

2. Do not cut off unused cables! Wind them together and tie them back! They may

be used later to install additional features.

Speedometer signal (ISO connector A):

Connect the black/white cable A1 from cable harness to the tapping position of the
speedometer signal.

Note: Many cars are supplied with the speedometer signal on one of the car radio
connectors. Ask your car dealer for more information.

A

A

A

A

Never tap the speedometer signal from the ABS control!

Pin no.

Cable color

Connection

A1

black/white

speedometer signal input

A2

white/yellow

back-up lights (reversing signal)

A3

white/brown

mute signal output (open collector)

A4

red

+12V permanent power supply, (via cable fuse
10 A if necessary)

A5

white/blue

not used

A6

grey

switch input low beam (do not connect to dash-
board illumination!)

A7

violet

+12V switched, (must not be interrupted during
engine start)

A8

brown

negative battery pole

Audiovox_MS5000.book Seite 49 Donnerstag, 9. November 2000 3:41 15