Auto Sanitising (Filtration)

The Xcelsior pump automatically maintains the filtration/sanitising of the spa pool water. The
minimum amount of filtration time is programmable by the user and can be adjusted up to 15
minutes per hour (6 hours per day). In order to maintain correct filtration of the pool water, the
controller monitors the time for which the pump runs in normal pool operation. If the pump has
only run for a short time, the system will automatically run the pump for an additional period
every hour to reach the minimum filtration time set by the user.

Adjusting Minimum Filtration Time

First push the Down and Jet 2 buttons together to display the

filtration time setting on the digital readout.

The default setting is 10 minutes per hour
(= 4 hours per day).
Holding down the Up Button

or Down Button

will adjust the filtration time setting between
0 and 15 minutes per hour in demand
heating mode, or 3 and 15 minutes in
Filtration only heating mode.

Adaptive Filtration Mode
Adaptive Filtration Mode is useful in high ambient temperatures where ambient heat adds to
the spa water temperature. In Adaptive Filtration Mode the spa will reduce the filtration time to
suit the temperature of the water. If the water temperature is climbing due to ambient heat, the
filtration times will be reduced accordingly.

To enable Adaptive Filtration Mode enter into
the Adjust Minimum Filtration Time mode as
described above, then press and hold the up
button until F.Ad is displayed.

To disable Adaptive Filtration Mode enter
into the Adjust Minimum Filtration Time mode
then press and hold the down button until you
reach the desired filtration time.

Clean Up Cycle

If desired, a clean up cycle can be initiated to filter the water after the spa pool has been used.
This is done by simply pushing the Jet 1 Button to leave auto mode and switch on the pump.
This will circulate the water through the filter for 45 minutes. After 45 minutes the system will
return to auto mode and maintain the temperature ready for the next time the spa pool is used.

– 5 –

Light Operation

Your spa may have been fitted with either of two different LED lights; a Spa Power Coloured
Light (SPCL) or a Spa Power Variable Coloured Light (SPVCL). The Spa Power Coloured Light
is a single coloured light that is either on or off. The Spa Power Variable Coloured Light is a
light that has the ability to change between 12 different colours and white (see below for user
instructions).

NOTE: Not to be used with Daisy Chain light systems with multiple point LED’s.

The multi-function Light Button is used to turn the light on and off (SPCL) and select

through the different operating modes of the Spa Power Variable Colour Light. Two short presses

of the button will turn the Spa Power Coloured Light on and off or five short presses of the button
will cycle the Spa Power Variable Coloured Light as follows:

Push 1 - Light ON (SPCL - On) (SPVCL Colour - White)
Push 2 - Light ADJUST (SPCL - Off) (SPVCL Adjustable Colour Mode)
Push 3 - Light CYCLE SLOW (SPVCL Cycle through colours - slowly)
Push 4 - Light CYCLE FAST (SPVCL Cycle through colours - quickly)
Push 5 - Light OFF (Default State)

Note: This is a multi-function button which performs the following -
1) Short presses of this button activate the light functions as detailed above.
2) Holding this button will begin to increase the set temperature of the spa.
3) When a Spa Power Variable Speed Blower is fitted and is turned on this button increases

the

blower speed.

Adjustable Colour Mode (SPVCL only)

When the light is on, short presses of the Down button will put the light into

adjustable colour mode and then sequentially select through all the available colours. The last

colour set in this mode will be remembered the next time the light is used.

Indicator Light

A small red dot in the bottom corner of the digital readout indicates when
the light is turned on.

If left on the light will automatically switch off after 30 minutes.