Program outline – Hired-Hand System 1000 Power Curtain Eight Stage Controller User Manual
Page 27

System 1000™ Power Curtain™ Controller
24
Resistance
(K ohms)
Temp (F)
Temp (C)
Resistance
(Kohms)
Temp (F)
Temp (C)
5.326
104.0
40.0
4.454
112.1
44.5
5.262
104.5
40.3
4.402
112.6
44.8
5.199
105.1
40.6
4.334
113.4
45.2
5.137
105.6
40.9
4.284
113.9
45.5
5.076
106.2
41.2
4.217
114.6
45.9
4.995
106.9
41.6
4.168
115.2
46.2
4.936
107.4
41.9
4.120
115.7
46.5
4.877
108.0
42.2
4.057
116.4
46.9
4.820
108.5
42.5
3.995
117.1
47.3
4.763
109.0
42.8
3.949
117.7
47.6
4.688
109.8
43.2
3.888
118.4
48.0
4.633
110.3
43.5
3.844
118.9
48.3
4.579
110.8
43.8
3.785
119.7
48.7
4.507
111.6
44.2
All resistance values given in Kohm’s.
16. Program Outline
1.
Timer Percentage
or
Variable Timer
Hi Temp
Hi Percent
Lo Temp
Lo Percent
2.
Ramp Function
Number Of Days
Ending Temperature
3.
Setup System
Sensors For Display
Unit Sensor(s)
Auto Kill Fans
Power Unit On/Off
Set Trend Index
Initial Drop Delay
4.
Program Stages
A.
Program Stage 1
1.
Mode
2.
Stage 1 Sensors
3.
Stage 1 Offset
4.
Stage 1 Differential
5.
* Stage on Timer
B.
Program Stage 2
1.
Mode
2.
Stage 2 Sensors
Step one will vary if expanded
timer is used in step 18.
* Only stages programmed with a
cool mode will be given the option of
being on a timer.