Rarely changed settings, Si g n al, Ear t h – Hired-Hand Farm Hand Series: Swine Finisher User Manual

Page 10

Advertising
background image

Part No. 4801-0150 Rev 8-04

Farm Hand Swine Finisher 5 Stage

10 of 32

R

HIRED-HAND

AL

AR

M N

.O

.

AL

AR

M N

.C

.

5

4

3

2

1

IN

ST
AG

ES

3

2

1

SENSORS

+

12V

SI

G

N

AL

GN

D

RE

T

HO

T

L1

L2

EAR

T

H

GN

D

LO

HI

5

4

3

2

1

FA

N

2

FA

N

1

IN

VAR FANS

STAGES OUT

SWX1

J5

J4

J3

J2

PRESSURE

AC POWER

HH NET

Curtain 1

Curtain 2

Cl

os

e

Op

e

n

Hot

Cl

os

e

Op

e

n

Hot

Signal

Signal

Control

Switches

PS3 - Calibrate Sensor 3

This reading can be changed by pressing the + or - button until the desired
reading is displayed.

7. Rarely Changed Settings















Settings which are rarely, or never changed are found on a bank of switches located inside the front panel
of the controller. The upper position is ON, the lower position is OFF. The functions of the switches are as
follows:

7.1 Switch Settings

SWX 1 - Lock

This switch is used to lock the controller. When it is on, the user may change settings such as
target temperature and minimum speed/timer percentages but they can not change the settings
in program mode. If the switch is set to ON the program settings are locked.

SWX 2 - Fahrenheit/Celsius

This switch toggles between Fahrenheit and Celsius operation. If the switch is set to ON the
controller will read the sensors as Fahrenheit. (Note: If you change this switch, you will have
to reset your tunnel on points and off points and your Target Temperature.)

SWX 3 - 5/10 minute timer

This switch selects between a 5 and 10 minute system timer. If the switch is ON, the timer is
10 minutes.

SWX 4 - Curtains independent

This switch is used to choose whether the curtain machines operate off the same sensor or if
they operate independently. If the switch is ON, the curtains are independent with curtain 1
running on sensor 1, and curtain 2 running on sensor 2.

SWX 5 - Tunnel On/Off

This switch is used to enable or disable the tunnel mode of the controller. When this switch
is in the OFF position, the controller will not go into tunnel for any reason.

SWX 6 - Tunnel On Stage

This switch tells the controller whether it is tunneling off of the lowest programmed tunnel
stage or if it is tunneling off of outside temperature. If this switch is set to the ON position,
the controller will switch to tunnel mode whenever the first programmed tunnel stage comes
on. If this switch is OFF, the controller will use the “Tunnel On Point” setting for entry into
tunnel.

SWX 7 - Power Ventilate

This switch indicates whether this is a power ventilated house or a natural ventilated house.
If it is a power ventilated house the controller will leave the inlet curtain closed until tunnel
mode is entered. This switch must be set to ON if you have a Power Ventilated house.