Controller installation and setup, Programming examples – Hired-Hand Farm Hand Series: Swine Finisher User Manual

Page 11

Advertising
background image

Part No. 4801-0150 Rev 8-04

Farm Hand Swine Finisher 5 Stage

11 of 32

SWX 8 - Program ‘A’ or ‘B’

This switch is used to toggle between 2 preset programs. This could be used to store separate
summer/winter programs for instance. The ON position is for Program A, and the OFF
position is for Program B.

8. Controller Installation and Setup

8.1 Installation

8.1.1 Tools Required

Mini Screwdriver

Standard Screwdriver

Wire Strippers

8.1.2 Installation Instructions

1. Unpack system, and check that all components are present.

1

Farm Hand Swine Finisher

1 Installation

Kit

1 Fuse

Kit

3 Sensors
1 Manual

2. Hang Farm Hand Swine Finisher with four screws and the plastic mounting brackets

included.

3. Make sure all power supplies are disconnected before breaking any wires, or reaching

into the enclosure.

4. Open Swine Finisher and find all connections. Refer to wiring diagrams in back of this

manual.

5. Run sensors out to locations inside the house. (Sensor 3 should be installed outside the

house.) Be sure that the sensors are in a safe location, free from any temperature
influences (direct sunlight, water, etc.) Use care when securing sensor wires so that you
do not cut the wire, Any short, or break in the wire will cause improper sensor operation.

6. Connect each sensor to its appropriate terminals inside the enclosure. (See wiring

diagrams in the back of this manual.)

7. Connect wires from stage terminals to the contactor panel, or relay box. See wiring

diagrams for locations of terminals.

8. Hookup three wire connections from Swine Finisher board to curtain machines. See

wiring diagrams for locations of terminals.

9. CHECK THE POSITION OF THE VOLTAGE SELECTOR SWITCH. Connect the

wires for 120/240V power to the terminals specified in the wiring diagram.

9. Programming Examples

When following these examples, you will need to refer to the Program Reference section to see which
options are available for each of the parameters(P1, P24, etc.).

9.1 Setting up a Stage

There are five parameters used in programming any stage. They are P1-P5. The following is an
overview of how to program a stage: