Hired-Hand Farm Hand Series: Swine Finisher User Manual

Page 26

Advertising
background image

Part No. 4801-0150 Rev 8-04

Farm Hand Swine Finisher 5 Stage

26 of 32

P21 -- Run Time

The number of seconds that the curtain machine will run
opening or closing at the beginning of each curtain cycle (See
Cycle Time).

P22 -- Initial Run Time

Number of seconds to run on the first drop from closed. This is
to be sure that you have cleared the top of the opening. This
setting only applies when the controller senses that the curtain
is closed when it begins its run.

P23 -- Degrees above

target (Unit 1)

Many times it is more cost effective to bring a slightly high
temperature back into range with a fan. This setting allows you
to specify a number of degrees above the target temperature
that the curtain will allow before trying to open.

P24 -- Degrees above

target (Unit 2)

Occasionally, a grower may want one curtain sidewall to drop
before the other to try to avoid large temperature swings. This
setting allows for this to happen. Note: If you would like
both curtain units to always react together, you must set
P23=P24.

P25 – Tunnel Onpoint

This is the sensor 3 temperature at which the controller will
enter tunnel mode. Only applicable when tunneling on outside
temperature.

P26 -- Tunnel Offpoint

This is the sensor 3 temperature at which the controller will
enter tunnel mode. Only applicable when tunneling on outside
temperature.

P27 -- Close Override

The degrees below target at which time the curtains will
override to close.

P40 - HHNet Address

Unique setting for controllers along a single network wire pair.
Only used with the PC compatibility feature using Hired-
Hand’s Farm Manager software.

P41 -- Version Number

This is the version of the software for the controller. This value
is not settable.

P42 -- Controller Type

This is a number that identifies the type of controller (Swine
Finisher) to the Farm Manager Software (PC compatible)

PS1 - Calibrate Sensor 1

The temperature the controller reads from Sensor 1. This
setting is used only when calibrating sensors. Press the +
and/or - buttons until the correct reading is seen in the main
display. (See Sensor Calibration)

PS2 - Calibrate Sensor 2

The temperature the controller reads from Sensor 2. This
setting is used only when calibrating sensors. Press the +
and/or - buttons until the correct reading is seen in the main
display. (See Sensor Calibration)

PS3 - Calibrate Sensor 3

The temperature the controller reads from Sensor 3. This
setting is used only when calibrating sensors. Press the +
and/or - buttons until the correct reading is seen in the main
display. (See Sensor Calibration)

Advertising