General machine description, Recommended processes & equipment, Design summary – Lincoln Electric IM480 CV-400 User Manual

Page 12

Advertising
background image

GENERAL MACHINE DESCRIPTION

The CV-400 is an SCR controlled three phase DC
power source. It is designed with a single range
potentiometer control.

RECOMMENDED PROCESSES
& EQUIPMENT

The CV-400 is supplied as a constant voltage power
source only. It is designed for all Innershield

®,

Outershield

®

and all solid wire and gas procedures

within the capacity of the machine. The output char-
acteristics have been optimized for these CV process-
es without use of a variable arc control.

The CV-400 is designed to be used with the LN-7,
LN-7 GMA, LN-8, LN-9, LN-9 GMA, LN-22, LN-23P*,
LN-25, or LN-742 semiautomatic wire feeders, the NA-3,
NA-5 and NA-5R automatics within the capacity of the
machine. The CV-400 Diode option is required to uti-
lize the cold start and cold electrode sensing features
of the NA-3, NA-5 and NA-5R.

* For “Cold” gun use K350 Adapter Kit.

DESIGN SUMMARY

Operational Features & Controls

ARC CHARACTERISTICS

Through the unique combination of the transformer,
three phase rectifier, capacitor bank, and output
choke design, in conjunction with the solid state con-
trol system, an outstanding constant voltage welding
performance is achieved with a fixed pinch setting
optimized for the most popular arc characteristics.

OUTPUT VOLTAGE CONTROL

The OUTPUT voltage control, a small 2 watt poten-
tiometer, is calibrated from 1 to 10.

MACHINE OUTPUT CONTROL SWITCH “LOCAL”
OR “REMOTE”

The machine output voltage can be controlled by
either the “OUTPUT CONTROL” on the machine con-
trol panel, the output control on the wire feed unit, or
an optional “remote control” that is available. This
switch selects the mode of control, either “LOCAL” or
“REMOTE”.

POLARITY SELECTION

Polarity selection is made by appropriately connecting
the electrode and work welding cables to either the

+

” stud or to the “

-

” stud. Select “VOLTMETER”

switch for “

+

” or “

-

” electrode, for the remote (#21)

work sensing lead.

VOLTMETER SWITCH “+” ELECTRODE OR “-”
ELECTRODE

This switch selects electrode polarity for the remote
(#21) work sensing lead of automatic or semiautomat-
ic equipment.

115 VOLT POWER SWITCH

The power input contactor operates from an auxiliary
115 volt transformer that is energized through the
POWER toggle switch on the machine control panel.
I ” is on and “0” is off.

PILOT LIGHT

A white light on the machine control panel indicates
when the power source input contactor is closed. This
means the main power transformer and all auxiliary
and control transformers are energized.

THERMAL PROTECTION LIGHT

An amber light on the machine control panel indicates
when either of the two protective thermostats have
opened. Output power will be removed but input
power will still be applied to the machine.

INPUT CONTACTOR

The power source is equipped with an input contactor.

12

Advertising