20

OUTPUT CONTROL “LOCAL-REMOTE” SWITCH

The Output Control toggle switch on the control panel
labeled “Local-Remote” gives the operator the option
of controlling the output at the machine control panel
or at a remote station. For remote control, the toggle
switch is set in the “Remote” position and controlled at
the wire feed unit control, or by connecting a K775
control to terminals 75, 76, and 77 on the terminal
strip at the front of the machine, or by connecting a
K857 control with a K864 adapter to the 14-pin con-
nector on the front of the machine. For control at the
machine control panel (Output Voltage control dial),
the toggle switch is set in the “Local” position.

(Exception: When used with an LN-9, LN-9 GMA or
NA-5 wire feeder, the Output Control switch must be
in the “Remote” position or automatic shutdown of the
LN-9 or NA-5 may occur.)

POLARITY SELECTION

Polarity selection is made by appropriately connecting
the electrode and work welding cables to either the

+

” stud or to the “

-

” stud. Select “Voltmeter” switch

for “

+

” or “

-

” electrode for the remote (#21) work sens-

ing lead.

VOLTMETER SWITCH

Select “

+

” for positive electrode or “

-

” for negative

electrode. This switch selects electrode polarity for the
remote (#21) work sensing lead of automatic or semi-
automatic equipment.

THERMAL PROTECTION LIGHT

The amber thermal protection light will be lit if either of
the two protective thermostats have opened. The out-
put power will be disabled but input power will still be
applied to the welder.

115 VAC and 42 VAC AUXILIARY POWER AND
CONTROL CONNECTIONS

14-Pin Connector

The 14-pin connector receptacle (type MS-3102A-2D-
27SX) supplies auxiliary power.

42 VAC is available at receptacle pins I and K.
A 10 amp circuit breaker protects this circuit.

115 VAC is available at receptacle pins A and J. A 10
amp circuit breaker protects this circuit. Note that the
42 VAC and 115 VAC circuits are electrically isolated
from each other.

FRONT VIEW OF 14-PIN CONNECTOR
RECEPTACLE

PIN

LEAD NO.

FUNCTION

A

32

115 VAC

B

GND

Chassis Connection

C

2

Trigger Circuit

D

4

Trigger Circuit

E

77

Output Control

F

76

Output Control

G

75

Output Control

H

21

Work Connection

I

41

42 VAC

J

31

115 VAC

K

42

42 VAC

L

---

---

M

---

---

N

---

---

F = 7 6

G = 7 5

H = 2 1

I = 4 1

J = 3 1

K = 4 2

A = 3 2

B = G N D

C = 2

D = 4

E = 7 7

L

N

M