Installation – Lincoln Electric IM731 INVERTEC V350-PRO User Manual

Page 11

Advertising
background image

A-4

INSTALLATION

A-4

LN-10 Connection Instructions

An LN-10 can only be used with the “Factory” &

Advanced Process”” versions of the 350-Pro.

• Turn the Invertec power switch "off"

• Connect the K1505 control cable from the LN-10 to the

14-pin MS-style connector.

• Connect the electrode cable to the output terminal of

polarity required by the electrode. Connect the work

lead to the other terminal.

• Set the meter polarity switch on the front of the Invertec

to coincide with wire feeder polarity used.

• See the LN-10 manual for details on accessing Control

DIP Switch

LN-15 Connection Instructions

(Factory, Construction & Advanced Process versions

can be connected.

• Turn the Invertec power switch "off".

• Connect the electrode cable to the output terminal of

polarity required by electrode. (See Figures below)

• Set the meter polarity switch on the front of the Invertec

to coincide with wire feeder polarity used.

LN-25 Connection Instructions

(Factory, Construction & Advanced Process versions

can be connected.

• Turn the Invertec power switch "off".

• Connect the electrode cable to the output terminal of

polarity required by electrode. Connect the work lead to

the other terminal.

• LN-25 with Remote Control options can be used with the

Factory and Advanced Process version of the V350. The

6-Pin (K444-1) and 14-pin (K444-2) remotes can be con-

nected directly to the 6-pin & 14-pin MS-style connectors.

The 42 Volt Remote Voltage and Output Control (K624-1)

Kit can be connected to the V350ʼs 14-pin MS-style con-

nector using Remote Control Cable assembly K627- [ ].

LN-25s with a K431-1 remote kit can be connected to the

V350ʼs 14-pin MS-style connector using a K432 cable and

K876 adapter. (See connection diagram S19899). Or the

K432 cable could be modified with a K867 Universal

Adapter Plug (See connection diagram S19405) to con-

nect it to the V350ʼs 14-pin MS-style connector.

LN-742 Connection Instructions

An LN-742 can only be used with the “Factory” &

Advanced Process”” versions of the 350-Pro.

• Turn the Invertec power switch "off"

• Either a K591 or a K593 Input cable assembly is

required to connect the LN-742 to the Invertec.

• Connect the control cable from the LN-742 to the

14-pin MS-style connector.

• Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect the

work lead to the other terminal.

• Set the meter polarity switch on the front of the

Invertec to coincide with wire feeder polarity used.

The wire feeder will now display the welding volt-

age.

• If a remote control such as K857 is to be used with the

LN-742, the remote can be connected directly to the 6-

pin MS-style connector on the front of the Invertec or use

a K864 adapter to connect the LN-742 and the remote to

the 14-pin MS-style connector.

Cobramatic Connection Instructions

A Cobramatic can only be used with the “Factory” &

Advanced Process”” versions of the 350-Pro.

• Turn the Invertec power switch "off"

• Connect the control cable from the Cobramatic to

the 14-pin MS-style connector.

• Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect the

work lead to the other terminal.

• Set the meter polarity switch on the front of the

Invertec to coincide with wire feeder polarity used.

• If a remote control such as K857 is to be used with

the Cobramatic, the remote can be connected

directly to the 6-pin MS-style connector on the front

of the Invertec or use a K864 adapter to connect

the cobramatic and the remote to the 14-pin MS-

style connector.

TIG Module K930-2

The TIG Module connects to the Factory and Advanced

Process V350-Pro versions with a K936-1 (9-14 pin)

control cable. Connect the K936-1 to the MS-style

connector.

The TIG Module can also be used with the V350-Pro

Construction version. A K936-4 control cable is

required to supply 115VAC to the TIG Module from

an external 115VAC supply.

INVERTEC® V350-PRO

Work
Clamp

Electrode Cable

Electrode Cable

Electrode Cable

Work
Clamp

Work
Clamp

wire feeder
K1870-1

wire feeder
K1870-1

RANGER 8
SAE 400 WITH CV ADAPTER

ENGINE DRIVEN WELDERS
WITH WIRE FEED MODULE
(LOCAL MODE AND CV ADAPTER)

CV250
CV300
CV400

CC POWER SOURCE

Output Terminals
Always Hot.

Output Terminals
Always Hot.

Output Terminals
Always Hot.

Order K484 Jumper
Plug Kit.

Electrode Cable

Work
Clamp

semiautomatic

semiautomatic

semiautomatic

semiautomatic
wire feeder
K1870-1

wire feeder
K1870-1

wire feeder
K1870-1

CV655, DC400, DC600,
DC655, V350-PRO,

RANGER 9, RANGER 300 DLX
COMMANDER 300
COMMANDER 500
RANGER 2V35050
RANGER 305G

Output Terminals

Output Terminals
Always Hot.

Always Hot.

Power source contactor

Power source contactor
switch must be in the

switch must be in the
"ON" position or use a

"ON" position or use a
K848 Junper Plug Kit.

K848 Junper Plug Kit.

ACROSS THE ARC MODEL

V350-PRO

TWIST-MATE

CONTROL CABLE MODEL

Electrode Cable