Operation – Lincoln Electric IM731 INVERTEC V350-PRO User Manual

Page 20

Advertising
background image

B-8

OPERATION

B-8

INVERTEC® V350-PRO

LN-10/DH-10 Wire Feeder Compatibility Note:

The LN-10 and DH-10 feeders can be used to pulse weld

and in the power mode with the panel. The displays on the

LN-10 & DH-10 do not show the wire feed speed or power.
8. HOT START and ARC CONTROL features have different

functions depending on the welding Mode that is active.

Each feature is described under the welding mode head-

ing. (See Item 7 or 7.A for specified Mode Operations)

(See Figure 1 or 2)

LOWER CASE PANEL (See Figure 1)

The output studs, line switch and remote connector are

located on the lower case front.

9. Both terminals are "Twist-Mate" connectors.

The Negative terminal is configured to accept the pass

through gas system except Code 11445, which has no

gas pass-through and is equipped with “Tweco” connec-

tors).

10. The METER POLARITY switch is located above the out-

put connectors. The switch provides a work connection

for wire feeder voltmeters. Place the switch in the posi-

tion of the electrode polarity indicated by the decal. The

switch does not change the welding polarity.

11. 6-pin MS-style connector for remote control.

12. 14-pin MS-style connector for wire feeder connection

and remote control.

REMOTE CONTROL of the OUTPUT CONTROL and

WELD TERMINALS

The Invertec V350-Pro has auto sensing of remote output

controls. If after connecting or removing a remote, the

Invertec V350-Pro did not configure the way you would like

the local or remote control settings can be changed by

pushing the OUTPUT CONTROL or WELD TERMINAL but-

ton. (A user cannot select between the 6 and 14 pin MS-

style connectors.)

CV modes

• The remote will default to the 14-pin MS-style connector if

a remote is connected. If no remote is connected to the

14-pin MS-style connector then the remote will default to

the 6-pin MS-style connector if a remote is connected to it.

• In all of the CV modes, the WELD TERMINAL control will

default to REMOTE.

TIG mode

• The remote will default to the 6-pin MS-style if a remote

control is connected to the 6-pin MS-style and to the 14-

pin MS-style connector. If a remote is not connected to the

6-pin MS-style connector then the remote will default to

the 14-pin MS-style connector if a remote is connected.

• If a remote control is connected to any of the MS-style

connectors the WELD TERMINAL control will default to

REMOTE. If there are not any remote control devices

attached the WELD TERMINAL control will default to ON.

CC-Stick modes

• The remote will default to only the 6-pin MS-style connec-

tor if a remote is connected to it.

• The WELD TERMINAL control will default to ON with or

without a remote connected.

Types of Remote OUTPUT CONTROL

• The Invertec V350-Proʼs Output Control can be controlled

by either a potentiometer connected between 77 & 75 with

the wiper connected to 76 or a 0V to 10V DC supply con-

nected between 76 & 75. (76 needs to be positive)

• 14-Pin Ms-style connector lead 75 is pin G, lead 76 is pin

F and lead 77 is pin E.

• 6-Pin Ms-style connector lead 75 is pin C, lead 76 is pin B

and lead 77 is pin A.

Potentiometer Control

• The total resistance should be between 2000 ohms (2K)

and 10,000 ohms (10K)

• The machine output will be at minimum when lead 76

(wiper) is at the end of the potentiometer that is connected

to 75. The machineʼs output will increase as the wiper of

the potentiometer is moved to the end that is connected to

77. (Note: In TIG mode, moving the lead 76 (wiper) to lead

77 would produce the current that has been set by the

Invertec V350-Proʼs front panel Output Control.)

• Remotes of this type offered by Lincoln Electric are the

K857, K812 and K870.

Voltage Control

• The supply should be an isolated supply. (Not referenced

to earth ground, any auxiliary power from the Invertec

V350-Pro or the welding output) The supply should be

capable of supplying at least 20mA.

• 0 volts supplied to 76 will set the Invertec V350-Pro to

minimum output for the mode that has been selected

while 10 volts supplied to 76 will set the Invertec V350-Pro

to the maximum output for the mode. (Note: In TIG mode,

10 volts supplied to lead 76 would produce the current

that has been set by the Invertec V350-Proʼs front panel

Output Control.)

Types of Remote WELD TERMINAL Control

• The Invertec V350-Proʼs Weld Terminals can be con-

trolled from each of the MS-style connectors. The circuit

has a nominal OCV of 15VDC and requires a dry contact

closure (less than 100 ohms) to activate the output of the

Invertec V350-Pro.

• 14-Pin MS-style connector, the Weld Terminals are con-

trolled from pin C (lead 2) and pin D (lead 4). Pin C is posi-

tive.

• 6-Pin MS-style connector, the Weld Terminals are con-

trolled from pin D (lead 2) and pin E (lead 4). In the 6-pin

MS-style connector pin D is positive.

Advertising