D-1

MAINTENANCE

D-1

VISUAL INSPECTION

Clean interior of machine with a low pressure air

stream. Make a thorough inspection of all compo-

nents. Look for signs of overheating, broken leads or

other obvious problems. Many problems can be

uncovered with a good visual inspection.

ROUTINE MAINTENANCE

1. Every 6 months or so the machine should be

cleaned with a low pressure airstream. Keeping

the machine clean will result in cooler operation

and higher reliability. Be sure to clean these areas:

• All printed circuit boards

• Power switch

• Main transformer

• Input rectifier

• Auxiliary Transformer

• Reconnect Switch Area

• Fan (Blow air through the rear louvers)

2. Examine the sheet metal case for dents or breakage.

Repair the case as required. Keep the case in good con-

dition to insure that high voltage parts are protected and

correct spacings are maintained. All external sheet

metal screws must be in place to insure case strength

and electrical ground continuity.

PERIODIC MAINTENANCE

Overload Protection

The machine is electrically protected from producing

high output currents. Should the output current

exceed 430A, an electronic protection circuit will

reduce the current to approximately 100A. The

machine will continue to produce this low current until

the protection circuit is reset. Reset occurs when the

output load is removed.

Thermal Protection

Thermostats protect the machine from excessive

operating temperatures. Excessive temperatures may

be caused by a lack of cooling air or operating the

machine beyond the duty cycle and output rating. If

excessive operating temperature should occur, the

thermostat will prevent output voltage or current. The

meter will remain energized during this time.

Thermostats are self-resetting once the machine cools

sufficiently. If the thermostat shutdown was caused by

excessive output or duty cycle and the fan is operating

normally, the Power Switch may be left on and the

reset should occur within a 15 minute period.

INVERTEC® V350-PRO

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or

electrode with skin or wet clothing.

• Insulate yourself from work and

ground

• Always wear dry insulating gloves.

------------------------------------------------------------------------

EXPLODING PARTS can cause

injury.

• Failed parts can explode or cause other

parts to explode when power is applied.

• Always wear a face shield and long

sleeves when servicing.

------------------------------------------------------------------------

See additional warning information

throughout this Operatorʼs Manual

-----------------------------------------------------------

WARNING

CAPACITOR DISCHARGE PROCEDURE

1. Obtain a power resistor (25 ohms, 25 watts).

2. Hold resistor body with electrically insulated glove.

DO NOT TOUCH TERMINALS. Connect the resis-

tor terminals across the two studs in the position

shown. Hold in each position for 1 second. Repeat

for all four capacitors.

3. Use a DC voltmeter to check that voltage is not

present across the terminals on all four capacitors.

CAPACITOR
TERMINALS

RESISTOR

Advertising