INSTALLATION

A-5

INVERTEC® V350-PRO

General Instructions for Connection of Wire

Feeders to V350-Pro

Wire feeders other than those listed above may be

used provided that the auxiliary power supply rating of

the V350-Pro is not exceeded. K867 universal adapter

plug is required. See connection diagram S24985 on

page F-4.

REMOTE CONTROL OF INVERTEC

Remote Control K857, Hand Amptrol K963 and Foot

Amptrol K870.

UNDERCARRIAGE MOUNTINGS

PARALLEL OPERATION

The V350-Pro are operable in parallel in CC mode.

For best results, the currents of each machine should

be reasonably equally balanced. As an example, with

two machines set up in parallel for a 400 amp proce-

dure, each machine should be set to deliver approxi-

mately 200 amps, not 300 amps from one and 100

amps from the other. This will minimize nuisance

shutdown conditions. In general, more than two

machines in parallel will not be effective due to the

voltage requirements of procedures in that power

range.

To set machine outputs, start with output control pots

and arc control pots in identical positions. Use the

output control pots to balance the currents and main-

tain the desired current. The arc control pots should

be kept identical on the two machines.

M19527

6-01

14.79

12.44

3.44

21.06

27.82

5.50

10.00

MOUNTING HOLE LOCATIONS

13.10

1/4-20 NUT (4 PLACES)

NOTE: MOUNTING SCREWS CANNOT PROTRUDE MORE THAN 0.5 INCHES INSIDE THE MACHINE.

3.50

11.84