AvailabilityExample2
AppendixB.OverallEquipmentEfficiencyExamples
IM8000
CheckPoint™UserManual
B.3
TimeStamp
Status
Duration
TimeinPlannedDowntime
TimeNotinPlannedDowntime
3:00PM
Disconnected
3603
0
3603
4:00PM
Disconnected
3603
3603
0
* Alltimeslistedinseconds.
Availability for Each Hour
CalculatingtheAvailabilityfactorforeachhourresultsinthefiguresinTable14.4.Rememberthatwhen
theAssetScheduledTimeisequaltothePlannedDowntime,Availabilityis0%(e.g.,11:00AMinTable
14.4).
Table14.4
AvailabilityFactorforEachHour*
Hour
Disconnected
Time
AssetSched.
Time
Planned
Downtime
Planned
Prod.Time
Unplanned
Downtime
Operating
Time
Availability
6:00AM
3603
0
0
0
0
0
0%
7:00AM
3602
0
0
0
0
0
0%
8:00AM
3603
0
0
0
0
0
0%
9:00AM
3602
0
0
0
0
0
0%
10:00AM
3583
0
0
0
0
0
0%
11:00AM
1811
1791
1791
0
0
1791
0%
12:00PM
3603
0
0
0
0
0
0%
1:00PM
3602
0
0
0
0
0
0%
2:00PM
3601
0
0
0
0
0
0%
3:00PM
3603
0
0
0
0
0
0%
4:00PM
0
3603
3603
0
0
3603
0%
* Alltimeslistedinseconds.
Availability for the Entire Shift
TocalculatetheAvailabilityfortheentireshift,youusethetotalsfromthevarioustimecolumnswiththe
followingresults.
Disconnected
Time
AssetScheduled
Time
Planned
Downtime
PlannedProduction
Time
Unplanned
Downtime
Operating
Time
Availability
34213
5394
5394
0
0
5394
0%