Lincoln Electric IM8002 POWER WAVE MANAGER User Manual
Page 40

Chapter 6. Power Source Settings
Cable Settings and Tests
6.6
Power Wave® Manager User Manual
IM8002
Figure 6.4 Sense Lead Diagnostics
NOTE |
You cannot perform this test with ServoTorch.
Automatic Test
Power Wave® Manager can also help you troubleshoot sense lead issues. The software automatically
attempts to detect the sense lead location by turning on the Welding Power Source’s output in an
open circuit voltage (OCV) mode and reading back voltage. The system does this while stepping
through the various manual sense lead locations, determining which location is most likely the one
being used.
STOP |
Make sure your welding circuit is open before performing
this test.
To perform the automatic test, choose the Detect sense lead location automatically option in Power
Wave® Manager and click the Test sense lead selection button.