13

13

RANGER 8 LPG

Wire Feed Welding Processes
(Constant Voltage)

The only Innershield

®

electrode recommended for use

with the Ranger 8 is NR

®

-211-MP. The electrode

sizes and welding ranges that can be used with the
Ranger 8 are shown in the following table:

Diameter Wire Speed Approximate

(in.) Range In./Min. Current Range

.035

80 - 110

75A to 120A

.045

70 - 130

120A to 170A

.068

40 - 90

125A to 210A

The Ranger 8 is recommended for limited “MIG” weld-
ing (GMAW - gas metal arc welding). The recom-
mended electrodes are .030” and .035” L-50 and L-
56. They must be used with a blended shielding gas
such as C25 (75% Argon - 25% CO

2

). The welding

ranges that can be used with the Ranger 8 are shown
in the following table:

Diameter Wire Speed Approximate

(in.) Range In./Min. Current Range

.030

80-110

75A to 120A

.035

70-130

120A to 170A

Summary of Welding Processes

CONTROL ELECTRODE

CABLE IDLE WHEN NOT TO START

PROCESS USED MODE WELDING WELDING

STICK

No

AUTO

Hot

Touch electrode to work.
Welding starts immediately
and engine goes to high
idle.

TIG/K930-1/K938-1/

Yes

HIGH

Cold

Press Amptrol, contactor

K936-[ ]/K892-1

closes, welding starts

(WITH AMPTROL)

immediately.

WIRE FEED, LN-25 WITH

No

AUTO

Cold

Press gun trigger, LN-25

INTERNAL CONTACTOR

contactor closes. Welding
starts immediately and
engine goes to high idle.
NOTE: Output Control
must be set above “3”.

WIRE FEED, LN-7 WITH

Yes

HIGH

Cold

Press gun trigger,

K240 CONTACTOR KIT

contactor closes. Welding
starts immediately.

It is recommended that the Ranger 8 be used in HIGH
idle when using the TIG Module. It can be used in the
AUTO position but the delay going to low idle after
welding is ceased will be increased if the AFTER-
FLOW CONTROL is set above 10 seconds.

Auxiliary Power

The Ranger 8 can provide up to 8,000 watts of
115/230 volts AC, single phase 60 Hz power for con-
tinuous use. The front of the machine includes three
receptacles for connecting AC power plugs; one 50
amp 115/230 volt NEMA 14-50R receptacle and two
15 amp on (Codes 10541 Below), 20 amp on
(Codes 10937 Above) 115 volt NEMA 5-15R recepta-
cles.

Do not connect any plugs that connect to the
power receptacles in parallel.

-----------------------------------------------------------------------

Start the engine and set the “IDLER” control switch to
the desired operating mode. Set the “CONTROL” to
10. Voltage is now correct at the receptacles for aux-
iliary power.

115V Duplex Receptacles

The 115V auxiliary power receptacles should only be
used with three wire grounded type plugs or approved
double insulated tools with two wire plugs.